DVM832
V. 01 26/01/2016 8 ©Velleman nv
9.3 DC CURRENT
Do not measure circuits that may contain voltages
> 500 V
range
resolution
accuracy
200 µA
0.1 µA
± (1.5 % rdg + 2 digits)
2000 µA
1 µA
20 mA
10 µA
200 mA
100 µA
± (2.0 % rdg + 2 digits)
10 A
10 mA
± (2.0 % rdg + 3 digits)
Overload protection: F0.5 V/600 V, F10 A/600 V fuse
Note: 10 A up to 10 seconds
9.4 RESISTANCE
Do not conduct resistance measurements on live
circuits
range
resolution
accuracy
200
0.1
± (1.0 % rdg + 5 digits)
2000
1
± (1.0 % rdg + 3 digits)
20k
10
200k
100
2000k
1k
± (1.5 % rdg + 3 digits)
Overload protection: F0.5 V/600 V fuse
9.5 DIODE AND CONTINUITY
Do not conduct diode or continuity measurements on
live circuits
range
description
test condition
display reads the
approximate forward
voltage of the diode
forward DC current ± 10 µA
reversed DC voltage ± 1.8 V
built-in buzzer sounds
if resistance < 50
open-circuit voltage ± 1.8 V
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Velleman DVM832 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Velleman DVM832 in the language / languages: English, German, Dutch, French, Polish, Portuguese, Spanish as an attachment in your email.

The manual is 0,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info