9.1. Allgemeines
Max. Eingangsspannung
600V CAT IV, 1000V CAT IV
Display
6000 Zählungen, 3 Samples pro Sek.
Überlastungsschutz
µAmA-Bereich: 630mA/1000V (Ø10.3x38mm)
10A-Bereich: 10A/1000V (Ø10.3x38mm)
Temperaturkoeffizient
0.1x /°C (<18°C oder >28°C)
Stromversorgung
9V NEDA 1604 6F22 006P (mitgelief.)
Bereichseinstellung
manuell/ automatisch
Polaritätsanzeige
"-"-Ablesung
Außenbereichsanzeige
"OL" automatische Ablesung
Lo-Bat-Anzeige
" "-Ablesung
Arbeitstemperatur
0°C bis 40 °C (<80%RH, <10°C nicht-kondensierend)
Lagertemperatur
-10°C bis 60 °C (<70%RH, ohne Batterie)
Abmessungen
190x90x40mm
Gewicht
±500 g (Batterie mitgeliefert)
9.2. DC Gleichspannung
Bereich
Auflösung
Genauigkeit
660mV
100µV
(0.5% der Ablesung + 5 Digits)
6.6V
1mV
(0.8% der Ablesung + 5 Digits)
66V
10mV
660V
100mV
1000V
1V
(1.0% der Ablesung +2 Digits)
Eingangsimpedanz: >10M für jeden Bereich
9.3. AC Wechselspannung
Bereich
Auflösung
Genauigkeit
660mV
100µV
(1.0% der Ablesung + 5 Digits)
60Hz
6.6V
1mV
40~400Hz
66V
10mV
660V
100mV
1000V
1V
(1.5% der Ablesung +2 Digits)
Eingangsimpedanz: >10M für alle Bereiche
Frequenzbereich: 40 bis 400Hz
Überlastungsschutz: 1000Vdc oder ac rms.
9.4. DC Gleichstrom
Bereich
Auflösung
Genauigkeit
660µA
0.1µA
(1.0% der Ablesung + 3 Digits)
6.6mA
1µA
66mA
10µA
(1.5% der Ablesung + 3 Digits)
600mA
0.1mA
10A
10mA
(1.8% der Ablesung +5 Digits)
Für Strommessungen bis zu max. 10A verwenden Sie den 10A-Anschluss. Bei
Strommessungen > 7A und max. 15 Sekunden: warten Sie 15 Min.
Überlastungsschutz : 600mA-Bereich Sicherung F630mA/1000V 10A-Bereich
Sicherung F10A/1000V
67


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Velleman DVM4200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Velleman DVM4200 in the language / languages: English, German, Dutch, French, Spanish as an attachment in your email.

The manual is 1,18 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info