622286
7
Zoom out
Zoom in
Previous page
1/76
Next page
DVM1200 VELLEMAN
- 7 -
Diode Test
To test a diode out of a circuit:
1. Set the rotary switch to range.
2. Press SELECT to activate the function.
3. Connect the black and red test leads to the COM and terminals respectively.
4. For forward-bias readings on any semiconductor component, place the red test lead on the component’s
anode and place the black test lead on the cathode.
5. The meter will show the approximate forward voltage of the diode.
In a circuit, a good diode should still produce a forward bias reading of 0.5V to 0.8V. However, the reverse-bias
reading can vary depending on the resistance of other pathways between the probe tips.
Continuity Check
To test for continuity:
1. Set the rotary switch to range.
2. Press SELECT twice to activate the function.
3. Connect the black and red test lead to the COM and Ω terminals respectively.
4. Connect the test leads to the resistance in the circuit being measured.
5. When the test lead to the circuit is below 50Ω, a continuous beeping will indicate it.
NOTE: Continuity test is available to check open/short of the circuit.
Capacitance Measurement
The meter's capacitance ranges are 60.00nF, 600.0nF, 6.000F, 60.00F and 300.0F.
To measure capacitance:
1. Set the rotary switch to the proper range.
2. Connect the black and red test leads to the COM and terminals respectively. You can also measure the
capacitance by using the special multi-function socket.
3. Connect the test leads to the capacitor being measured and read the displayed value.
Some tips for measuring capacitance:
The meter may take a few seconds to stabilize the reading. This is normal for high-capacitance measuring.
To improve the accuracy of measurements less than 60nF, subtract the residual capacitance of the meter
and leads.
Below 600pF, the accuracy of measurements is unspecified.
To avoid electrical shock and/or damage to the instrument, disconnect the circuit power and
discharge all high-voltage capacitors before testing diodes.
To avoid electrical shock and/or damage to the instrument, disconnect the circuit power and
discharge all high-voltage capacitors before testing the continuity.
To avoid electrical shock and/or damage to the instrument, disconnect the circuit power and
discharge all high-voltage capacitors before measuring capacitance. Use the DC voltage
function to confirm that the capacitor is discharged.
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Velleman DVM1200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Velleman DVM1200 in the language / languages: English, German, Dutch, French, Italian, Polish, Spanish as an attachment in your email.

The manual is 1,41 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info