6
Height (cm) 91
Width (cm) 51
Depth (cm) 46
Weight (kg) 190
Output 3-7 kW
Nominal output 5.0 kW
Heated area 30-105 m2
Efficiency 81%
EEI 108
Flue gas data: 265°C at 25°C, 12 pa.
Technical data, Aura 3 Stone
Combustion chamber: (H x W x D):
24.5-36.0x30.0x28.0 cm
Smoke outlet Ø 15 cm
Installation height, top: 86 cm
Distance to non-flammable material:
510 cm (recommended)
Distance to flammable material:
Rear=12.5 cm, Side=30 cm, Front=80 cm
19
Maintenance:
As with anything else that you use on a daily basis, your stove must of course be maintained.
You should only clean your stove when it is cold. Wipe the outside using a dry cloth, and you
should clean it regularly on the inside. The actual combustion chamber should be cleaned of ash,
soot and tar remnants. You should also remove the smoke guide plate, because dirt and soot
will build up behind it, and check that there is free access through the flue and chimney. You
should also check that the gaskets in the door and ash pan are not worn out. If the gaskets do
not seal properly, they must be replaced. Remember to lubricate the door hinges as required.
Glass
We recommend the use of VARDE glass cleaner to clean the pane; this can be bought from our
dealers.
The ash pan must be emptied regularly, and the ash can be disposed of along with your
domestic waste. But you must of course make sure that the ash does not contain any embers. If
you are unsure about how to clean or maintain your wood-burning stove, contact the dealer who
sold you the unit or contact your chimney inspector.
In particular, following a long period of time where you have not used the stove, before using it
again you must make sure that there is nothing blocking the flue or the chimney.
Some exposed areas of the stoves painted surface can over time become w orn out
e.g. through cleaning or overheating of the wood-burning stove. However, this can be repaired
using a special coating, Senotherm®, which comes in a spray can and can be purchased from
your dealer.
The panels in the combustion chamber are known as vermiculite panels and will become worn
over time. If a piece of wood damages a vermiculite panel, it has no effect on combustion. You
do not need to replace the panels unless the crack in the panel is more than about ½ cm wide.
Only original spare parts from Varde Ovne A/S may be used.
The door is fitted on a lock spring, which pulls the door in. This is a regulatory requirement in
certain countries. The spring is attached to the hinge, and can be removed if you do not wish to
have a spring-loaded door.
No unauthorised alterations may be made to the wood-burning stove.
All of the exterior parts of the wood-burning stove will become very hot during use.
You should therefore exercise necessary caution.
IMPORTANT!!
Chimney fires
If your chimney catches fire, you must follow this procedure:
- Close all of the air supplies to the stove and telephone 112.
(Most chimney fires will go out on their own once you have stopped any air from getting into the
stove).
As a minimum, you must contact your chimney inspector, who will then inspect the stove and
chimney for damage.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Varde Aura 3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Varde Aura 3 in the language / languages: English as an attachment in your email.

The manual is 1.59 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Varde Aura 3

Varde Aura 3 Additional guide - English - 12 pages

Varde Aura 3 Usermanual and installation guide - English - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info