Troubleshooting.
Smoke enters the room:
Not enough draught in the chimney.
Inspect the smoke pipe or the chimney for blockage.
Clean the inside of the stove removing soot from the upper ver-
miculite / smoke plate.
Make sure the height of the chimney is correct.
The glass or the chimney soot up:
The wood is too moist.
Not enough secondary air is applied to the combustion process.
You may have shut off the supply of primary air too early when
lighting up the stove.
There always have to be clear flames in the combustion chamber.
The heat is emitted from the stove:
The wood is too moist (all energy goes into drying it) or of a poor
quality.
Inspect the position of the smoke plate and make sure there is free
passage for the smoke.
Combustion is too intense:
Gaskets in the door or the ash-pan are no longer tight and need
replacement.
The chimney draught is too strong - apply a draught control.
The shaking grate is stuck:
Inspect the grate for jammed wood, nails or the like.
Make sure the lever is placed correctly.
Height of chimney
If in doubt, contact your local
stove dealer. He will be able
to inform you of the correct
height.
4
English
Congratulations on purchasing
your new stove from
VARDE OVNE A/S
Kongevej 246, DK - 6510 Gram
Before lighting up your Varde stove for the first time, we recommend that you
read these instructions carefully and contact your local stove vendor or building
authorities to inquire about existing regulations regarding the installation of
stoves. Please follow these regulations closely.
Please Note! You are by law required to register your stove at the local chim-
ney-sweeper.
Until installation keep the stove dry and not too cold. The stove cannot stand
moisture.
Please note, that an existing chimney, not necessarily is effective enough for a
new modern stove.
2. edition 26.07.2010 FOR-177 GB Installation- and User guide
Warranty
All Varde stoves go through a close quality inspection, and we take pride in always delivering
products of a consistent quality. This being so, manufacturing faults may still occur, and on
these we offer a 5 year warranty.
The warranty does not include:
· Wearing parts, such as the Vermiculite fire bricks in the combustion chamber, the smoke
plate, glass, gaskets, cast iron bottom and the shaking grate.
· Damages which occur as a consequence of misuse, such as overheating, incorrect installa-
tion, missing or wrong maintenance etc. (see instructions earlier).
· Damages caused by external influences of a physical character.
· Cost of transportation in connection with warranty repairs.
· Assembling/reassembling in connection with warranty repairs.
· Compensation for following damages, including damage on other objects.
Warranty conditions:
These instructions for use are also your proof of warranty. The warranty will not take effect
until vendor’s stamp, information about model, registration number and date of purchase
(invoice if possible) have been applied below. In case of claims, please bring this proof of
warranty to your local vendor.
Model:
Reg.no.:
Date of
purchase:
Vendor´s stamp and signature
These instructions for use pertain to the following line of
DS / EN 13240
approved stoves:
Varde Aura 1
Varde Aura 2
Varde Aura 3
Varde Aura 11
These stoves is designed for intermittent combustion and can be
connected to a chimney used by other fireplaces, as long as the
appropriate rules and regulations are adhered to.
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Varde Aura 3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Varde Aura 3 in the language / languages: English as an attachment in your email.

The manual is 0.28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Varde Aura 3

Varde Aura 3 User Manual - English - 12 pages

Varde Aura 3 Additional guide - English - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info