Installation distances:
The stove must, in accordance with the applicable regulations, comply with the following
minimum distances to combustible walls and materials:
From the sides: 30 cm
Rear: 12.5 cm
Distance to furniture: 80 cm
NB: Note that B (from chimney to the wall) is a recommendation. There may be
different local/national rules.
Aura 1, 11, 2, 3 and 3 Stone
A 12,5 cm C 30 cm
B 22,5 cm D 80 cm
Aura 2
Aura 3 and Aura 3 Stone
Aura 1 and 11
15
How to light up and use your stove:
When you use the stove for the first time, the surface coating will cure and smoke will come
from the stove and it will have a slightly pungent smell, which will disappear after a good airing.
We therefore recommend that you open the doors and windows so there is airflow to/from
outside.
During the curing process, the coating will become soft and vulnerable, so therefore avoid
touching the coated surfaces. We also recommend that you regularly open and close the door
during the first couple of hours to avoid the doors gasket from becoming stuck to the coating.
Never use flammable liquids such as spirits or petrol w hen you light the fire!
We recommend that you light the fire using the Top-Downmethod, where you light the wood
at the top of the combustion chamber rather than at the bottom. This method is the most
eco-friendly way to light a fire. At the same time, it will be easier to keep the glass in the door
clean.
Cross 2-4 small pieces of kindling on the combustion chambers base plate
(approx. 0.71.1 kg). Position them so that there is a small gap between the individual pieces.
On top of these, place 812 small wooden pins (0.40.7 kg), and place 1-2 kindling blocks on
the top and in between the wooden pins. In total, about 1.5 kg wood.
It is easier to light the fire if there is a thin layer of ash in the base of the stove.
Before you light the fire, air must flow up through the base grate, and the air rosette in the ash
pan for the kindling air must be open, and the damper above the door for the combustion air
must be drawn to the right so that it is completely open for the combustion air.
When the fire is burning well, remember to close the kindling air again, since the stove and
chimney otherwise can become overheated and the warranty for the stove and chimney will be
void. Remember to check that the ash pan has also been closed correctly.
However, in most cases you will need to find the best setting for the combustion air yourself,
due to: the chimney draught, chimney height, quality of the fuel etc. all this play a crucial role
in how your stove operate best.
If the stoves nominal heat output becomes too great in relation to your heating requirements,
you can reduce the heat output as follows:
- Use a smaller amount of fuel than normally, e.g. 0.91.2 kg and ideally consisting of 2 smaller
pieces of wood. Apply full air to light the wood properly, then reduce the combustion air,
perhaps down to 30%. However, you must not reduce it so much that it causes the fire to go
out. There must always be clear flames.
Using this method, depending on the chimney draught, quality of the fuel, etc., you can reduce
the stoves heat output from a nominal 5.0 kW to perhaps 3-3.5 kW.
Note that if you reduce the combustion air too much, this can lead to poor combustion, which
will result in reduced efficiency and increased emission value in the smoke (increased pollution).
When re-stoking the fire, we recommend that you first open the door and load new wood when
there are only embers left inside the combustion chamber. If there are flames, then smoke and
gas are still being generated, and depending on the efficiency of your chimney, there is a danger
that smoke downdraught will enter the room.
When re-stoking, use gloves when loading the wood.
If you experience problems with lighting the fire and its function, see the section:
How to correct a fault.
To achieve the nominal heat output, below setings is recommended, this may vary as a consequence of
the chimneys effectiveness:
First firing
amount
[kg]
Kindling
air
[%]
Combustion air
[%]
Nominal
output
[kW]
Chimney
- draught
[PA]
Efficiency
[≥ in %]
Re-stoking
interval at
nominal output
[minutes]
1,3 0 (closed) approx. 60 5.0 12 81 approx. 45
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Varde Aura 1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Varde Aura 1 in the language / languages: English as an attachment in your email.

The manual is 1.59 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Varde Aura 1

Varde Aura 1 Additional guide - English - 12 pages

Varde Aura 1 Usermanual and installation guide - English - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info