INSTALLATION INSTRUCTIONS
Wall holder model 044.01 - 044.02 -
044.03 - 044.04 - 044.05 - 044.06
Model 044.01 (Fig. 1)
Basic model with ON-OFF switch.
Model 044.02 (Fig. 2)
Model with 16 A European standard socket and ON-OFF switch.
Model 044.03 (Fig. 3)
Model with 10 mA (*) differential switch, 16 A European standard
socket and ON-OFF switch.
Model 044.04 (Fig. 4)
Model with 10 mA (*) differential switch and ON-OFF switch.
Model 044.05 (Fig. 5)
Model with universal shaver socket (**) and ON-OFF switch.
Model 044.06 (Fig. 6)
Model with 10 mA (*) differential switch, universal shaver socket
(**) and ON-OFF switch.
(*) The appliance is equipped with a 10 mA differential switch.
(**) A safety transformer isolates the shaver socket from the
mains electricity and a protective device prohibits the use of
appliances with a power greater than 20 VA.
Installation of wall holder
This work should only be carried out by a suitably qualified electrical
engineer, in order to comply with the existing national safety regulations.
When the spiral cord is extended to its maximum length, the hairdryer
shall not be reached by a person using the bath or the shower.
There are two possible methods of installation:
A = for fixed connection lead
B = for mobile connection lead
Attention: before installing the hairdryer
always switch off the general switch
of your mains electricity.
Method A (for fixed connection lead) for
wall holder model 044.01 - 044.04
044.05 - 044.06
The connection wiring from the mains for wall holder models
044.01 - 044.04 - 044.05 - 044.06 must be type 2x1,5 mm2.
1. Separate the cover (1) of the wall holder from the back plate by
loosening the screw (14).
2. Remove the knockout (2) provided in the back plate of the wall
holder.
3. Feed the mains supply cable (3) coming out of the wall into the
hole in the back plate left after removing the knockout (2).
4. Secure the back plate of the wall holder to the wall using the plugs
and screws provided.
5. Remove the terminal connector (4), connect the mains supply
cable (3) to the terminal connector (4), as shown in the picture, and
then secure again the terminal connector (4).
6. Model 044.01 - 044.04 - 044.05 - 044.06 are double insulated
and no earth connection is provided.
7. Fit the front cover of the wall holder, taking care to locate the cable
sleeve (6) properly. Secure the front cover with the screw (14).
8. Switch on the general switch of your mains electricity. The
hairdryer is ready for use.
Method B: (for mobile connection lead)
only for wall holder model 044.01 - 044.04
044.05 - 044.06
The connection wiring from the mains for wall holder models 044.01
044.04 - 044.05 - 044.06 must be type H05VV-F 2x1,5 mm2.
1. Separate the cover (1) of the wall holder from the back plate by
loosening the screw (14).
2. Remove the knockout (8) provided in the base of the back plate
of the wall holder for feeding the cable sleeve (11).
3. Secure the back plate of the wall holder to the wall using the plugs
and screws provided.
4. Strip the power supply connection cable (13), insert the cable
bushing (11), remove the terminal (9), connect the cable (13) to
the terminal (9) and reposition the terminal (9). Position the
stripped part of the cable carefully, as indicated in the picture.
Secure the cable bushing (10) using the corresponding screws.
Caution: this appliance has double insulation and is not fitted with
an earthing system.
5. Locate the cable sleeves (6) and (11) in the slot provided in the
base of the back plate.
6. Fit the front cover of the wall holder, taking care to locate the cable
sleeves (6) and (11) properly.
7. Secure the front cover with the screw (14).
8. Switch on the general switch of your mains electricity. The
hairdryer is ready for use.
Method C (with mobile connection) for
models 044.02 - 044.03
See Method B: only variant:
- The power cable for mounts 044.02 - 044.03 must be type
H05VV-F 3G x 2.5 mm2and must be connected to the tripolar
terminal (7)
OPERATING INSTRUCTIONS
Switching
Wall mount switch (Fig. 7, 1)
appliance placed in the mount = off
appliance out of the mount = on
Differential switch
(Mod. 044.03, 044.04, 044.06 only)
The differential switch (Fig. 9 and 10), in the event of a fault in the
electrical circuit to which it is connected, is triggered and cuts off the
power supply to the mount and the hair dryer. (Fig. 9)
Allow your appliance to cool before storing away and do not wrap the
supply cord around the hairdryer in storage.
The A-weighted sound pressure level of the hairdryers for commercial use
is below 70 dB(A).
00060753 int_giu2018_Layout 1 05/06/2018 12:46 Pagina 7
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Valera Valera Premium Protect 1200 Shaver at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Valera Valera Premium Protect 1200 Shaver in the language / languages: All languages as an attachment in your email.

The manual is 2.09 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info