Installation instructions – auroMATIC 560 0020008427_0120
6 Start-up
6.1 Setting system parameters
Certain system parameters have to be set in order to
optimise the system for the respective conditions. These
parameters are all together on one operating level and
should only be set by the heating engineer.
You can access this operation level by pressing the pro-
gramming button "P" for roughly 3 seconds.
Display Turn the dial to adjust Setting range Factory setting
Changing the hydraulic plan 1, 2, 3 1
Adjusting the flow rate in l/min.
Transfer the value set at the solar station
flow rate limiter taking the unit used by this
specific flow rate limiter into account!
0 –165 l/min 3.5 l/min
Resetting the solar yield.
The solar yield is reset to 0 by turning the
dial to 1.
--
Resetting the operating hours.
The operating hours are reset to 0 by turning
the dial to 1.
--
Setting the max. temperature for cylinder 1 20 to 90 °C 75 °C
Table 6.1 System parameters
a
Caution!
The maximum permissible temperature of the
cylinder used (MAXT 1) must not be exceeded.
All system parameters can then be called up consecu-
tively by clicking the dial. You can specify the required
values by turning the dial. The value set can be saved by
clicking the dial.
When you press the P button, the display returns to
basic operating level without saving the adjusted value.
The following table gives an overview of all system pa-
rameters and their factory settings:
6 Start-up
32


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant VRS 560 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant VRS 560 in the language / languages: English as an attachment in your email.

The manual is 3,88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vaillant VRS 560

Vaillant VRS 560 Usermanual and installation guide - Dutch - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info