469501
11
Zoom out
Zoom in
Previous page
1/40
Next page
11Operating manual – auroMATIC 560 0020008427_01
5.5.4 Setting the timer program, circulation pump
You can create a customised timer program for a con-
nected circulation pump (only possible for hydraulic
plan 1), just as you can for the reheating function.
The controller is equipped with a default program for
this as well:
Time window Weekday/
Block of days
Start time End time
H 1 M0 - S0 6:00 22:00
H 2
H 3
Table 5.5 Default circulation pump program
You can access the timer program for the circulation
pump by pressing programming button "P" and turning
the dial until the pump symbol appears in the display in-
stead of the water tap symbol. The setting of the de-
sired heating times is done in the same manner as the
setting of the heating times for the reheating function
(see Sec. 5.5.3). Set up the timer program so that the
circulation pump only operates at times when you ex-
pect a supply of hot water will be needed. Otherwise the
circulation pump operates unnecessarily and inadvert-
ently cools down the cylinder.
5.6 Activating the special functions
Display Required steps
Advance
Press the special function button once-
the party symbol flashes for approx. ten
seconds in the display, then the function
is activated. The function is deactivated
automatically when the next reheating
window begins.
If you want to deactivate the function
before, simply reselect the function.
The function can only be activated in the
reheating operation mode .
One-time reheating
Press the special function button twice -
The one-time reheating symbol flashes in
the display for approx. ten seconds, then
the function is activated.
If you want to deactivate the function
before, simply reselect the function.
Holiday function
Press the special function button three
times - the holiday function symbol flash-
es in the display for approx. ten seconds,
and you can use the dial to set the
number of holidays. Finally, the function
is activated for the set time.
If you want to deactivate the function
before, simply reselect the function.
If the anti-Legionnaire’s disease function
is activated, the protection will be car-
ried out on the last holiday.
Table 5.6 Activating the special functions
6 Error messages
The auroMATIC 560 solar controller shows error mes-
sages in the main operating level if there is a problem
with the temperature sensor.
The sensor configuration will always be displayed when
the controller is switched on for the first time, or if the
power supply has been switched off and on again. De-
pending on the set hydraulic plan, the controller recog-
nises whether there is an error, or if the sensor is not
necessary for operation.
a
Caution!
Never try to repair or carry out maintenance
work on the controller yourself. Call in an ap-
proved technician. We recommend concluding a
maintenance contract for your solar system
with a recognised handicraft business.
The following table explains the error messages.
Display Message/Description
Error cylinder sensor 1
This error occurs if the there is a prob-
lem with the connected sensor.
Error cylinder sensor 2
This error occurs if the there is a prob-
lem with the sensor, or if it is not con-
nected.
Error cylinder sensor 3
This error occurs if the there is a prob-
lem with the connected sensor.
Table 6.1 Error messages
No error messages are output for collector sensors Kol 1
and Kol 2. A plausibility check is still possible, e.g. by
comparing the collector temperature with the outside
temperature.
Operation 5
Error messages 6
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant VRS 560 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant VRS 560 in the language / languages: English as an attachment in your email.

The manual is 3,88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vaillant VRS 560

Vaillant VRS 560 Usermanual and installation guide - Dutch - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info