0020237057_00 Installation instructions 31
A.17 aroTHERM and gas-fired condensing boiler (eBUS), heat pump cascade option
Cylinder Equipment Heating cir-
cuits
Setting for
System
diagram
VR 70 VR 71
Buffer cylinder Domestic hot water cylinder downstream
of low loss header/buffer cylinder
Buffer cylinder charging using the system
controller
1 direct
1 mixed
16 1
allSTOR buffer cylinder Domestic hot water cylinder downstream
of low loss header/buffer cylinder
Buffer cylinder charging using the system
controller
1 direct
1 mixed
16 3
Buffer cylinder Domestic hot water cylinder downstream
of low loss header/buffer cylinder
Buffer cylinder charging using the system
controller
3 mixed 16 3
allSTOR buffer cylinder 3 mixed 16 6
B Overview of the setting options
B.1 Installer level
Setting level Values Unit Increment, select Default setting
Min. Max.
Installer level
Enter code 000 999 1 000
Installer level Service information Enter contact details
Phone number 1 12 Numbers 0 to 9, blank spaces, hyphen
Installer 1 12 Figures A to Z, 0 to 9, space
Installer level Service information Service date
Next service on Date
Installer level System configuration
System ----
Fault status Current value*
Water pressure Current value bar
System status Current value Standby, Heat. mode, Cooling,
DHW
Frost protect. delay 0 12 h 1 4
OT constant heating off, -25 10 1 off
Control modules Display Software version
Adaptive heat. curve Current value Yes, No No
Configure heat. circ. All, Zone Zone
Automatic cooling Yes, No No
Start OT cooling 10 30 1 21
Source regeneration Yes, No No
Current room air hum. Current value %
Current dew point Current value
Hybrid manager triVAI, Biv. point Biv. point
Heat. bivalence point -30 20 1 0
DHW bivalence point -20 20 1 -7
* If no fault is present, the status is No fault. If there is a fault, Fault list appears and you can read the fault message in the "Fault mes-
sages" section.
31


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant VRC 700F-4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant VRC 700F-4 in the language / languages: English as an attachment in your email.

The manual is 1,3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info