665294
31
Zoom out
Zoom in
Previous page
1/40
Next page
11Installation Instructions VRC430 0020042468_02
Dis-
play
screen
Title display
screen
adjustable operat-
ing values
(only display = A)
Remarks Unit Min.
value
Max.
value
Step width Preset
value
C1 HC1
Information
Supply target (A) Flow temperature tar-
get value
°C 1
Pump status (A) On, Off
FBG connection/
room actual value
Remote control con-
nected?
Room actual display
°C Yes, no and
0.5
C3 Hot water genera-
tor
information
Installation sensor
VF1 (A)
Actual value at the
feed sensor 1 or the in-
ternal sensor of the
heat generator
°C 1
Flame status
boiler (A)
Off, heating
mode, hot
water mode
C4 Hot water infor-
mation
current hot water
set target value (A)
Hot water set target
temperature of the
storage tank
°C 1
Storage probe 1 (A) Actual cylinder hot
water temperature
°C 1
Circulation pump
status (A)
On, Off
C8 HC1
parameters
Heating circuit type
(A)
Status display Heating cir-
cuit, inactive
Switch-on room
temperature
selectable with wall
mounting of the con-
troller or remote con-
trol
none,
modulating,
thermostat
none
Summer operation
mode Offset
If the outside tempera-
ture > target room tem-
perature + Summer
Offset, the boiler
switches off
R0301 1
C9 HC1
parameters
Set-back tempera-
ture
You can specify a set-
back temperature for
the times between the
holiday periods.
If your expert techni-
cian has set the frost
protection function,
the set-back tempera-
ture is automatically
5 °C. There will be no
display as set-back
temperature
°C 5 30 1 15
Heating curve in accordance with
the diagram operating
instructions
Chapter 4.7.3
0,2 4 0,05-0,1 1,2
Minimum tempera-
ture
Minimum feed temper-
ature
°C 15 90 1 15
C16 Hot water param-
eters
Legionella protec-
tion day
Day or block of days;
The cylinder is heated
to 70 °C for an hour
OFF, MO, TU,
WE, TH, FR,
SA, SU, MO-
SU
OFF
Legionella protec-
tion start time
0:00 24:00 0:10 4:00
Table 6.2 Display screens in expert technician level
Initial start-up 6
31


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant VRC 430 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant VRC 430 in the language / languages: English as an attachment in your email.

The manual is 4,76 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email