665294
17
Zoom out
Zoom in
Previous page
1/40
Next page
17Operating Manual VRC 430 0020042468_02
The comment field contains the text "Select target
room temperature".
Press the right-hand dial.
The input field is highlighted.
Turn the right-hand dial until the desired value is
displayed (values from 5 °C to 30 °C in
increments of 0.5 °C and frost protection function
are possible).
Press the right-hand dial.
The desired target room temperature or the frost func-
tion are set. The display jumps highlighted to normal.
4.7.3 Entering parameters for the heating circuit
You can enter the following parameters:
Set-back temperature
Outside the specified time windows, the heating is re-
duced to the set-back temperature.
If your expert technician has set the frost protection
function, the set-back temperature will automatically
be 5 °C. There is no display of set-back temperature.
Heating curve
The relationship between the outside temperature and
the required heating feed temperature is represented
in a diagram having various different heating curves
(see Fig. 4.15). Each heating curve (from 0.2 - 4.0)
gives a value for the heating flow temperature (verti-
cal diagram axis) for the individual outside tempera-
ture (horizontal diagram axis).
Fig. 4.15 Diagram with heating curves for a target room tem-
perature of 20 °C
Example:
If you select a heating curve of 1.5 with a target room
temperature of 20 °C, the controller provides a heating
flow temperature of 56 °C at an outside temperature of
0 °C.
The various heating curves indicate whether the heating
flow temperature should be higher or lower depending
on the outside temperature.
h
Note!
In a well-insulated apartment a comfortable
room temperature can be achieved even with a
flat heating curve. This saves heating energy.
Your expert heating technician will provide ad-
vice as to which heating curve should be se-
lected.
Proceed as follows to enter the parameters (example
heating circuit 1):
Turn the left-hand dial until screen 8 "HC1 param-
eters" is displayed.
> Select temperature
HC1
8
Set back temperature
Parameter
Heating curve
15 . 0 ° C
1 . 2
Fig. 4.16 Display screen 8 (example)
Turn the right-hand dial until the cursor
is in front
of the input field for the set-back temperature.
The comment field contains the text "Set temperature".
Press the right-hand dial.
The input field is highlighted.
Turn the right-hand dial until the desired value is
displayed (values from 5 °C to 30 °C in
increments of 0.5 °C are possible).
Press the right-hand dial.
The desired set-back temperature is set. The display
jumps highlighted to normal.
Turn the right-hand dial until the cursor
is in front
of the heating curve value.
The display field shows the text "set heating curve" in
the comment field.
Press the right-hand dial.
Operation 4
17
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant VRC 430 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant VRC 430 in the language / languages: English as an attachment in your email.

The manual is 4,76 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info