7Notices d'emploi et d'installation pour ballons uniSTOR, auroSTOR, geoSTOR 0020029429_02
5.2.2 Dimensions de l'appareil et des raccords
VIH S
Ø
b
D
B
M
L
K
J
I
H
G
F
E
t
C
A
3
4
5
6
7
8
9
10
11
1
2
Fig. 5.2 Dimensions de l'appareil et des raccords VIH S
Légende de la fig. 5.2
1 Raccord pour thermoplongeur (G1 1/2)
2 Trappe d'inspection (Ø120)
3 Raccord eau chaude (R1)
4 Départ chauffage (R1)
5 Douille d'immersion pour sonde de chauffage (Ø12)
6 Départ chauffage (R1)
7 Raccord de circulation (R3/4)
8 Départ solaire (R1)
9 Douille d'immersion pour sonde solaire (Ø12)
10 Retour solaire (R1)
11 Raccord eau froide (R1)
Type Unité VIH S 300 VIH S 400 VIH S 500
A mm 1775 1470 1775
B mm 279 308 308
C mm 1086 862,5 1062,5
D mm 500 650 650
E mm 1632 1301 1601
F mm 1546 1215 1515
G mm 1346 1065 1315
H mm 1196 965 1165
N mm 1086 862,5 1062,5
J mm 981 760 960
C mm 581 510 610
L mm 216 245 245
M mm 130 159 159
b mm 660 810 810
t mm 725 875 875
Tab. 5.1 Dimensions appareil VIH S
Installation 5
FR, CHFR,
BE
FR
45


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant VIH R 400 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant VIH R 400 in the language / languages: German, Dutch, French, Italian as an attachment in your email.

The manual is 4,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vaillant VIH R 400

Vaillant VIH R 400 User Manual - Dutch - 19 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info