4 Installation
VEN 5/5 classic; VEN 5/5 exclusiv26
Datei_001.eps
Fig. 4.5 Wall-mounting of appliance
Fig. 4.5 Accrochage de l’appareil
Afb. 4.5 Apparaat ophangen
4.3 Wall-mounting of appliance
● The fixing elements (screws, plugs, etc.) used for
attaching the appliance to the wall should be selected
with the weight of the unit (see technical
specifications) and the characteristics of the wall in
mind. The electric storage water heater should be
attached to the wall in a vertical position.
● Ensure that the bracket is in a horizontal position
before fixing it to the wall. The two outer holes are
used for actual attachment, while the hole in the
middle is provided to make it easier to center up the
appliance.
● Fit the VEN electric storage water heater, with the
holes for wall-hanging, by lowering it onto the
bracket, with the connection inlets of the under table
appliance pointing upwards, and those of the table
top appliance pointing downwards.
4.4 Water-connection valve assemblies
Caution!
The Vaillant electric storage water heater
must only be installed with a Vaillant low-
pressure valve assembly.
Please, also refer to the applicable price list.
Under table appliance
- VNU 1 for washstand, part no. 302 298
- VNU 1 for sink unit, part no. 302 299
- VNU 1 for sink unit with appliance connection,
part no. 000 414
- VNU 2 Standard, for washstand and sink unit,
part no. 302595
- VNU 2 (temperature-controlled) Standard, for
washstand and sink unit, part no. 302 596
- VNU 2 Design, part no. 302597
Table top appliance
- VNO 2 single-lever tap unit, part no. 000 420
- VNO 2 twin-lever tap unit, part no. 000 423
- Swiveling outlet, 250 mm, part no. 000 468
It is mandatory to have a pressure reducer installed if
the water-supply pressure exceeds 5 bar. Do not fit
hoses, spray-heads, anti-splash filters or similar
attachments to the tap outlet.
Caution!
Thoroughly read the installation instructions
supplied with the low-pressure valve
assembly before fitting.
VEN 007/0.eps