748443
23
Zoom out
Zoom in
Previous page
1/68
Next page
Produktbeschreibung 3
0020251834_00 uniTOWER Installations- und Wartungsanleitung 21
Angabe Bedeutung
Nomen-
klatur
230V Elektrischer Anschluss:
230V: 1~/N/PE 230 V
400V: 3~/N/PE 400 V
IP Schutzklasse
Symbole Kompressor
Regler
Kältemittelkreis
Heizkreis
Speicherbehälter, Füllmenge, zuläs-
siger Druck
Zusatzheizung
P max Bemessungsleistung, maximal
P Bemessungsleistung
I max Bemessungsstrom, maximal
I Anlaufstrom
Kältemit-
telkreis
MPa (bar) Zulässiger Betriebsdruck (relativ)
R410A Kältemittel, Typ
GWP Kältemittel, Global Warming Poten-
tial
Heiz-
kreis,
Warm-
wasser-
kreis
MPa (bar) Zulässiger Betriebsdruck
L Füllmenge
CE-Kenn-
zeichnung
siehe Kapitel „CE-Kennzeichnung
3.8 Anschlusssymbole
Symbol Anschluss
Heizkreis, Vorlauf
Heizkreis, Rücklauf
Kältemittelkreis, Heißgasleitung
Kältemittelkreis, Flüssigkeitsleitung
Symbol Anschluss
Warmwasserkreis, Kaltwasser
Warmwasserkreis, Warmwasser
3.9 CE-Kennzeichnung
Mit der CE-Kennzeichnung wird dokumentiert, dass die Pro-
dukte gemäß dem Typenschild die grundlegenden Anforde-
rungen der einschlägigen Richtlinien erfüllen.
Die Konformitätserklärung kann beim Hersteller eingesehen
werden.
3.10 Einsatzgrenzen
Das Produkt arbeitet zwischen einer minimalen und maxima-
len Außentemperatur. Diese Außentemperaturen definieren
die Einsatzgrenzen für den Heizbetrieb, Warmwasserbetrieb
und Kühlbetrieb. Siehe Technische Daten ( Seite 61). Der
Betrieb außerhalb der Einsatzgrenzen führt zum Abschalten
des Produkts.
3.10.1 Heizbetrieb
[-20;20]
[-20;43]
[20;55]
[-10;55]
[20;20]
A
B
30
35
40
45
50
55
60
25
20
15
10
5
0
-20 -15 -10 -5 0 5 10 15 20
A Außentemperatur B Heizwassertemperatur
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant uniTOWER split VWL at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant uniTOWER split VWL in the language / languages: German as an attachment in your email.

The manual is 5,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vaillant uniTOWER split VWL

Vaillant uniTOWER split VWL Usermanual and installation guide - Dutch - 68 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info