535146
19
Zoom out
Zoom in
Previous page
1/76
Next page
17Bedienungs- und Installationsanleitung Speicher uniSTOR, auroSTOR, geoSTOR 0020029429_02
10 Technische Daten
10.1 Technische Daten VIH S 300/400/500 und
VIH R 300/400/500
Einheit
VIH S VIH R
VIH S 300 VIH S 400 VIH S 500 VIH R 300 VIH R 400 VIH R 500
Speichernenninhalt l 300 400 500 300 400 500
tatsächlicher Speicherinhalt l 289 398 484 295 404 496
max. Betriebsdruck Speicher bar 10 10 10 10 10 10
max. Betriebsdruck Heizung bar 10 10 10 10 10 10
max. Warmwassertemperatur °C 85 85 85 85 85 85
max. Heizwasservorlauftemperatur °C 110 110 110 110 110 110
Bereitschaftsenergieverlust kWh/d 1,9 2,1 2,3 1,8 2,0 2,2
Heizungswärmetauscher:
Heizfläche des Wärmetauschers m
2
0,7 0,7 1,0 1,6 1,5 2,1
Heizwasserinhalt des Wärmetauschers l 4,7 4,5 6,6 10,7 9,9 14,2
Druckverlust im Wärmetauscher bei
max. Heizwasserbedarf mbar 11 11 16 75 75 125
Heizmittelstrom l/h 900 900 1250 2000 2000 2700
Warmwasserausgangsleistung bei
45/10°C
1)
l/10min 195 190 215 462 519 591
Warmwasserdauerleistung bei
Heizwassertemperatur 85/65°C
2)
kW 20 21 29 46 46 62
Warmwasserdauerleistung bei
Heizwassertemperatur 85/65°C
2)
l/h 491 516 712 1130 130 1523
Leistungskennzahl
1)
N
L
2,0 3,5 4,7 11,0 15,0 19,0
Solarwärmetauscher:
Heizfläche des Wärmetauschers m
2
1,6 1,5 2,1
Heizwasserinhalt des Wärmetauschers l 10,7 9,9 14,2
Druckverlust im Wärmetauscher bei
Solarbetrieb mit Solarflüssigkeit mbar < 10 < 10 < 10
Solarflüssigkeitsstrom l/h 200 300 500
Anschlüsse:
Kaltwasser- und Warmwasseranschluss Gewinde R1 R1 R1 R1 R1 R1
Zirkulationsanschluss Gewinde R
3
/
4
R
3
/
4
R
3
/
4
R
3
/
4
R
3
/
4
R
3
/
4
Vorlauf- und Rücklaufanschluss Gewinde R1 R1 R1 R1 R1 R1
Speicherabmessungen:
Breite mit Verkleidung mm 660 810 810 660 810 810
Tiefe mit Verkleidung mm 725 875 875 725 875 875
Höhe mm 1775 1470 1775 1775 1470 1775
Außendurchmesser Behälter ohne
Isolierung mm 500 650 650 500 650 650
Gewicht (inkl. Verpackung und
Isolierung) kg 150 169 198 125 145 165
Gewicht betriebsbereit gefüllt kg 439 567 682 420 549 661
Tab. 10.1 Technische Daten VIH S 300/400/500 und
VIH R 300/400/500
1)
nach DIN 4708, Teil 3
2)
Temperaturdifferenz Warm- Kaltwasser: 35 K
Technische Daten 10
DE, AT,
CH
DE, BEDE
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant uniSTOR VIH S 400 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant uniSTOR VIH S 400 in the language / languages: German, Dutch, French, Italian as an attachment in your email.

The manual is 4,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vaillant uniSTOR VIH S 400

Vaillant uniSTOR VIH S 400 User Manual - Dutch - 19 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info