System diagram 0020199565 11
0020200783_02 multiMATIC System diagram book 29
11 System diagram 0020199565
11.1 System diagram limitation
The cylinder temperature limiter, which serves to pre-empt
overheating, must be installed in a suitable location in order
to avoid cylinder temperatures above 100 °C.
11.2 Terminal assignment
11.2.1 VR 70 expansion module terminal
assignment
R1/S7: Solar pump
R2: Heating pump
R3: 3-way valve for increase in return flow
R4: Cylinder charging pump
R5/6: 3-way mixer
S1: Solar yield sensor
S2: Bottom temperature sensor of buffer cylinder
S3: Temperature sensor for a ΔT control system
S4: Temperature sensor for a ΔT control system
S5: Collector temperature sensor
S6: Flow temperature sensor
11.3 Required settings in the controller
System diagram: 2
Config.: VR70 addr. 1: 12
11.4 Required settings in the boiler
Auxiliary relay: Circulation pump