10 System diagram 0020199564
26 System diagram book multiMATIC 0020200783_02
10 System diagram 0020199564
10.1 System diagram limitation
The cylinder temperature limiter, which serves to pre-empt
overheating, must be installed in a suitable location in order
to avoid cylinder temperatures above 100 °C.
10.2 Terminal assignment
10.2.1 VR 70 expansion module terminal
assignment
R1/S7: Solar pump
R2: Heating pump
R3: 3-way valve for heating assistance
R4: Diverter valve for hot water generation
R5/6: 3-way mixer
S1: Solar yield sensor
S2: Bottom temperature sensor of buffer cylinder
S3: Temperature sensor for a ΔT control system
S4: Temperature sensor for a ΔT control system
S5: Collector temperature sensor
S6: Flow temperature sensor
10.3 Required settings in the controller
System diagram: 2
Config.: VR70 addr. 1: 12
10.4 Required settings in the boiler
Auxiliary relay: Circulation pump