Gas-doorstroomtoestel, type B
11BS
Toesteltype MAG 19/2 GXI 24/2 GXI
Nominaal vermogen
1)
(P) 19,2 24,4 kW
(instelling tussen 50 % - 100 %)
Nominale belasting
1)
(Q) 22,1 28,1 kW
(betrekking hebbend op de
verbrandingswaarde H
i
)
Min. vermogen 7,7 9,8 kW
Regelbereik 7,7-19,2 9,8-24,4 kW
Min. Schoorsteentrek p
w
0,015 0,015 mbar
Afvoermassastroom bij
max. vermogen 52 65 kg/h
min. vermogen 48 60 kg/h
Afvoertemperatuur bij
max. vermogen 180 155 °C
min. vermogen 110 110 °C
Warmwaterhoeveelheid bij
temperatuurkiezerpositie heet 2,5-5,5 2,5-7,0 l/min
temperatuurkiezerpositie warm 5,9-11,0 5,9-14,0 l/min
Noodzakelijke min. dynamische druk
2)3)
temperatuurkiezerpositie heet ca. 0,4 0,4 bar
temperatuurkiezerpositie warm ca. 0,6 0,65 bar
Vereiste minimale waterdruk
2)4)
temperatuurkiezerpositie heet ca. 0,6 0,75 bar
temperatuurkiezerpositie warm ca. 1,5 2,0 bar
Max. toegestane waterdruk 13 13 bar
Gasaansluitwaarde
Aardgas LL H
i
= 8,13 kWh/m
3
2,7 3,5 m
3
/h
Flessengas H
i
= 12,67 kWh/kg 1,8 2,2 kg/h
Aansluitdruk (dyn. gasvoordruk)
voor het apparaat
Aardgas 25 25 mbar
Flessengas 30 30 mbar
Gewicht ca. 13 14 kg
TECHNISCHE GEGEVENS
Vaillant B V
Paasheuvelweg 42 · Postbus 23250 · 1100 DT Amsterdam
Tel.: (20) 565 92 00
http://www.vaillant.nl
Technische gegevens
1)
Bij het werken met zuivere pro-
paan liggen de waarden ongeveer
12% lager.
2)
Drukverlies in het toestel bij volle-
dig geopende warmwaterkraan.
Met voor- en nageschakelde leidin-
gen dient in het bijzonder rekening
gehouden te worden.
3)
Druk waarbij het toestel normaal
functioneert.
4)
Druk waarbij de normale capaci-
teit wordt bereikt.
Voor schade die door het niet in acht
nemen van deze installatiehandleiding
ontstaan, nemen wij geen verantwoor-
ding.
10.003.668 NL01
83 4630NL
02
· 04/2002 · Wijzigingen voorbehouden · Gedrukt op 100% recycling papier
32


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant MAG 19-2 GXI R1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant MAG 19-2 GXI R1 in the language / languages: Dutch as an attachment in your email.

The manual is 0,37 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info