748496
35
Zoom out
Zoom in
Previous page
1/96
Next page
35Installatiehandleiding geoTHERM VWS/VWW 0020072959_00
Legenda bij afb. 6.10
3 Warmtepomp geoTHERM VWS/VWW
5 Warmwaterboiler
13 Weersafhankelijk energiebalansregelaar
16 Buitenvoeler/DCF-ontvanger
17 Drinkwaterstation
30 Zwaartekrachtrem
31 Regelklep
32 Kapventiel
33 Spatkap
42a Veiligheidsklep
42b Membraan-expansievat
42c Membraan-expansievat drinkwater
43 Veiligheidsgroep wateraansluiting
58 Vul- en aftapkraan
KP Circulatiepomp warmtepompcircuit
LP/UV1 Omschakelklep
SP Boilertemperatuurvoeler
WQ Warmtebroncircuit
VF2 Aanvoertemperatuurvoeler
ZH Elektrische extra verwarming
ZP Circulatiepomp
optioneel voor hydraulische ontkoppeling
45 Open verdeler
HK2-P CV-pomp met stuurleiding naar warmtepomp
De brijnpom is alleen bij VWS inbegrepen.
a
Attentie!
Gevaar voor beschadiging!
De elektrische extra verwarming moet
door een niet automatische terugzetten-
de alpolige temperaturbegrenzer worden
beveiligd.
a
Attentie!
Gevaar voor beschadiging!
Voor de warmtewisselaar in de waterbe-
reider is een wisseloppervlak van 1 m
2
per 3 - 4 kW verwarmingsvermogen van
de warmtepomp nodig.
h
Aanwijzing
Mocht een hydraulische ontkoppeling
van het CV-circuit noodzakelijk zijn, in-
stalleer dan een open verdeler alsmede
een externe CV-pomp zoals getoond in
afb. 6.10.
h
Aanwijzing
Als u tussen warmtepomp en CV-sy-
steem een open verdeler heeft geïnstal-
leerd, moet de temperatuurvoeler VF2 in
de aanvoerleiding van de open verdeler
naar het CV-systeem worden aange-
bracht.
Elektrische installatie 6
35


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant geoTherm VWS 300-2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant geoTherm VWS 300-2 in the language / languages: Dutch as an attachment in your email.

The manual is 4,22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vaillant geoTherm VWS 300-2

Vaillant geoTherm VWS 300-2 User Manual - German - 172 pages

Vaillant geoTherm VWS 300-2 User Manual - Dutch - 96 pages

Vaillant geoTherm VWS 300-2 User Manual - French, Italian - 172 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info