748567
71
Zoom out
Zoom in
Previous page
1/112
Next page
33Notice d'emploi geoTHERM plus VWS/VWW 0020025604_02
6.2 Caractéristiques techniques VWW
Désignation Unité VWW 62/2 VWW 82/2 VWW 102/2
Référence - 0010002794 0010002795 0010002796
Hauteur sans raccords
Largeur
Profondeur sans colonne
Profondeur avec colonne
mm
mm
mm
mm
1800
600
650
840
Poids total
- Avec emballage
- Sans emballage
- Opérationnel
- Poids de transport
- Module du ballon d'eau potable
- Module de la pompe à chaleur
kg
kg
kg
kg
kg
219
204
390
100
104
226
211
398
100
111
229
214
402
100
114
Tension nominale
- Circuit de chauffage/ventilateur
- Circuit de commande
- Chauffage d'appoint
-
3/N/PE 400 V 50 Hz
1/N/PE 230 V 50 Hz
3/N/PE 400 V 50 Hz
Fusible, passif A 3 x 16 3 x 16 3 x 16
Courant de démarrage
- Sans limiteur de courant de démarrage
- Avec limiteur de courant de démarrage
A
A
26
< 16
40
< 16
46
< 16
Puissance électrique absorbée
- min. sur W10W35
- max. sur W20W60
- Chauffage d'appoint
kW
kW
kW
1,5
3,1
6
2,1
3,8
6
2,5
4,9
6
Type de protection EN 60529 - IP 20
Raccord hydraulique
- Chauffage départ et retour
- Source de chaleur départ et retour
- Eau froide/eau chaude
mm
mm
mm
G 1 1/4", Ø 28
G 1 1/4", Ø 28
R 3/4"
Ballon d'eau potable intégré
- Contenu
- Pression de fonctionnement max.
- Température max. avec pompe à chaleur
- Temp. max. avec pompe à chaleur et
chauffage d'appoint
l
MPa (bar)
°C
°C
175
1 (10)
55
75
Circuit de la source de chaleur
- Pression de fonctionnement max.
- Température d'entrée min.
- Température d'entrée max.
- Débit volumique nominal dT 3K
- Hauteur de refoulement résiduelle dT 3K
- Débit volumique nominal dT 4K
- Hauteur de refoulement résiduelle dT 4K
- Puissance électrique absorbée pompe
MPa (bar)
°C
°C
0,3 (3)
4
20
1816
-
1362
-
-
2604
-
1953
-
3045
-
2284
-
Tabl. 6.2 Caractéristiques techniques VWW
Annexe 6
FR, CHfr
71


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant geoTHERM plus VWS 62-2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant geoTHERM plus VWS 62-2 in the language / languages: German as an attachment in your email.

The manual is 8,73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info