748442
63
Zoom out
Zoom in
Previous page
1/72
Next page
Bijlage
0020217097_04 flexoCOMPACT exclusive Installatie- en onderhoudshandleiding 63
VWF 58/4 VWF 88/4 VWF 118/4
Aardopwarmingsvermogen 100 (GWP
100
)
volgens verordening (EG) nr. 842/2006
1975 1975 1975
Type expansieklep
elektronisch elektronisch elektronisch
Toegestane bedrijfsdruk (relatief)
4,6 MPa
( 46,0 bar)
4,6 MPa
( 46,0 bar)
4,6 MPa
( 46,0 bar)
Compressortype
Scroll Scroll Scroll
Olietype
Ester (EMKARATE RL32-
3MAF)
Ester (EMKARATE RL32-
3MAF)
Ester (EMKARATE RL32-
3MAF)
Olievulhoeveelheid
0,75 l 1,25 l 1,25 l
Opstelplaats
VWF 58/4 VWF 88/4 VWF 118/4
Opstelplaats
binnen/droog binnen/droog binnen/droog
Volume opstelruimte EN 378
3,41 m³ 5,45 m³ 5,68 m³
Toegestane omgevingstemperatuur op de
opstelplaats
7 25 7 25 7 25
Toegestane relatieve luchtvochtigheid
40 75 % 40 75 % 40 75 %
O.2 Warmtebron brijn
Warmtebroncircuit/brijncircuit
VWF 58/4 VWF 88/4 VWF 118/4
Min. broninlaattemperatuur (brijn warm) in
het CV-bedrijf
10 10 10
Max. broninlaattemperatuur (brijn warm) in
het CV-bedrijf
25 25 25
Min. broninlaattemperatuur (brijn warm) in
het koelbedrijf
0 0 0
Max. broninlaattemperatuur (brijn warm) in
het koelbedrijf
30 30 30
Nominale volumestroom ΔT 3 K bij
B0/W35
1.290 l/h 2.320 l/h 3.000 l/h
Min. volumestroom bij continubedrijf bij
de gebruiksgrenzen
1.110 l/h 2.140 l/h 2.460 l/h
Max. volumestroom bij continubedrijf bij
de gebruiksgrenzen
1.290 l/h 2.320 l/h 3.000 l/h
Max. restopvoerhoogte bij ΔT 3 K bij
B0/W35
0,062 MPa
(0,620 bar)
0,039 MPa
(0,390 bar)
0,051 MPa
(0,510 bar)
Elektrisch opgenomen vermogen brijncir-
cuitpomp bij B0/W35 ΔT 3 K bij 250 mbar
extern drukverlies in het brijncircuit
44 W 62 W 64 W
Type brijnvloeistof
Ethyleenglycol 30% vol. Ethyleenglycol 30% vol. Ethyleenglycol 30% vol.
Afgiftecircuit/CV-circuit
VWF 58/4 VWF 88/4 VWF 118/4
Nominale volumestroom bij ΔT 5 K
B0/W35
920 l/h 1.530 l/h 1.920 l/h
Max. restopvoerhoogte bij ΔT 5 K B0/W35
0,065 MPa
(0,650 bar)
0,045 MPa
(0,450 bar)
0,035 MPa
(0,350 bar)
Nominale volumestroom bij ΔT 8 K
B0/W55
570 l/h 980 l/h 1.240 l/h
Max. restopvoerhoogte bij ΔT 8 K B0/W55
0,068 MPa
(0,680 bar)
0,065 MPa
(0,650 bar)
0,057 MPa
(0,570 bar)
Min. volumestroom bij continubedrijf bij
de gebruiksgrenzen
570 l/h 980 l/h 1.240 l/h
63


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant flexoCompact VWF at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant flexoCompact VWF in the language / languages: Dutch as an attachment in your email.

The manual is 3,5 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vaillant flexoCompact VWF

Vaillant flexoCompact VWF User Manual - Dutch - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info