14 Operating instructions ecoVIT exclusiv 0020258609_00
Appendix
A Status codes
Note
Since the code table is used for various products, some codes may not be visible for the product in question.
Statuscode Meaning
S.00 Heating: No heat de-
mand
Heating has no heat demand. The burner is off.
S.01 Heating mode: Fan start-
up
The fan start-up for heating mode is activated.
S.02 Heating mode: Pump
pre-run
The pump prerun for heating mode is activated.
S.03 Heating mode: Ignition The ignition for heating mode is activated.
S.04 Heating mode: Burner
on
The burner for heating mode is activated.
S.06 Heating mode: Fan over-
run
The fan overrun for heating mode is activated.
S.07 Heating mode: Pump
overrun
The pump overrun for heating mode is activated.
S.08 Heating mode: Anti-cyc-
ling time
The anti-cycling time for heating mode is activated.
S.20 DHW demand The domestic hot water demand is activated.
S.22 DHW mode: Pump pre-
run
The pump prerun for domestic hot water mode is activated.
S.24 DHW mode: Burner on The burner for domestic hot water mode is activated.
S.27 DHW mode: Pump over-
run
The pump overrun for domestic hot water mode is activated.
S.31 No heat demand: Sum-
mer mode
Summer mode is activated; there is no heat demand. The external control blocks heating mode.
S.34 Heating mode: Frost pro-
tection
The frost protection function for heating mode is activated.
B Troubleshooting
Symptom Possible cause Measure
No hot water, heating stays cold No gas 1. Check whether the gas stopcock in the building and the gas
stopcock on the product are open.
2. Open one or both of the gas stopcocks.
Installation isolator is closed 1. Check whether one of the isolators is closed.
2. Ask a competent person whether closed isolators can be
opened again.
No power supply 1. Check whether the power supply to the building and the main
switch on the product are switched on.
2. Switch on the power supply to the building and the main
switch on the product.
The display shows S.39 "Con-
tact thermostat activated" (e.g.
by the condensate pump or the
surface-mounted thermostat in
the underfloor circuit)
1. Clean the condensate pump with clean water in accordance
with the operating instructions for the condensate pump or
contact your approved heating specialist company.
2. Contact an approved heating specialist company.
Filling pressure in the heating
installation too low. F.22"Water
pressure too low" appears in
the display
1. Fill the heating installation. ( Page 11)
2. If the pressure drops too frequently, contact an approved
heating specialist company. The cause of the loss in heating
water must be established and eliminated.
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant ecoVIT exclusiv VKK 286-4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant ecoVIT exclusiv VKK 286-4 in the language / languages: English as an attachment in your email.

The manual is 0,9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vaillant ecoVIT exclusiv VKK 286-4

Vaillant ecoVIT exclusiv VKK 286-4 User Manual - German - 20 pages

Vaillant ecoVIT exclusiv VKK 286-4 User Manual - French - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info