42 Installatie- en onderhoudshandleiding ecoTEC plus 0020116691_05
Code Parameter Waarden of verklaringen
Fabrieksin-
stelling
Eigen in-
stelling
D.074 Legionellabeveiligingsfunctie
actoSTOR
0 = uit
1 = aan
1 = aan
D.075 Max. laadtijd voor warmwaterboiler
zonder eigen regeling
20 - 90 min 45 min
D.076 Toestelidentificatie (Device specific
number = DSN)
8 = VHR NL 20-24/5-5
12 = VHR NL 25-30/5-5; VHR NL 25/55 S
16 = VHR NL 30-34/5-5
19 = VHR NL 35-38/5-5; VHR NL 35/55 S
16 = VHR NL 34/5-5 I
niet verstel-
baar
D.077 Begrenzing van het boilerlaadvermo-
gen in kW
Instelbaar boilerlaadvermogen in kW
D.078 Begrenzing van de boilerlaadtempe-
ratuur in °C
55 °C - 80 °C
Aanwijzing
De gekozen waarde moet min. 15 K resp. 15 °C boven
de ingestelde gewenste boilerwaarde liggen.
75 °C
D.080 Bedrijfsuren verwarming in h niet verstel-
baar
D.081 Bedrijfsuren warmwaterbereiding in h niet verstel-
baar
D.082 Aantal branderstarts in CV-bedrijf Aantal branderstarts niet verstel-
baar
D.083 Aantal branderstarts in warmwater-
bedrijf
Aantal branderstarts niet verstel-
baar
D.084 Onderhoudsindicatie: aantal uren tot
de volgende onderhoudsbeurt
Instelbereik: 0 tot 3000 h en "---" voor gedeactiveerd „---”
D.088 Inschakelvertraging voor warmwater-
tapherkenning via vleugelwiel (alleen
product met geïntegreerde warmwa-
terbereiding)
0 = 1,5 l/min en geen vertraging,
1 = 3,7 l/min en 2 s vertraging
1,5 l/min
en geen
vertraging
D.090 Status digitale thermostaat herkend, niet herkend niet verstel-
baar
D.091 Status DCF bij aangesloten buiten-
temperatuurvoeler
geen ontvangst
ontvangst
gesynchroniseerd
geldig
niet verstel-
baar
D.092 actoSTOR moduleherkenning 0 = niet aangesloten
1 = verbindingsfout: geen communicatie via PeBus,
actoSTOR module werd vroeger herkend
2 = verbinding actief
niet verstel-
baar
D.093 Instelling toestelidentificatie (Device
Specific Number = DSN)
Instelbereik: 0 tot 99
D.094 Foutcode historie verwijderen Wissen van de foutlijst
0 = nee
1 = ja
D.095 Softwareversie PeBUS-componenten Printplaat (BMU)
Display (AI)
actoSTOR (APC)
HBI/VR34
niet verstel-
baar
D.096 Fabrieksinstelling Reset van alle instelbare parameters naar fabrieksinstel-
ling
0 = nee
1 = ja
D.097 Activering installateurniveau Code: 17
42


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant ecoTEC plus VHR NL 35-5-5S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant ecoTEC plus VHR NL 35-5-5S in the language / languages: Dutch as an attachment in your email.

The manual is 5,82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vaillant ecoTEC plus VHR NL 35-5-5S

Vaillant ecoTEC plus VHR NL 35-5-5S User Manual - Dutch - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info