Aanpassing aan de CV-installatie 8
0020116691_05 ecoTEC plus Installatie- en onderhoudshandleiding 27
8.6.1 Branderwachttijd instellen
1. Navigeer naar het Menu Installateurniveau Dia-
gnosemenu D.002 Max. wachttijd verwarming en
bevestig met .
2.
Stel de branderwachttijd in en bevestig met .
T
aanvoer
(ge-
wenst)
[°C]
Ingestelde maximale branderwachttijd [min]
1 5 10 15 20 25 30
30 2,0 4,0 8,5 12,5 16,5 20,5 25,0
35 2,0 4,0 7,5 11,0 15,0 18,5 22,0
40 2,0 3,5 6,5 10,0 13,0 16,5 19,5
45 2,0 3,0 6,0 8,5 11,5 14,0 17,0
50 2,0 3,0 5,0 7,5 9,5 12,0 14,0
55 2,0 2,5 4,5 6,0 8,0 10,0 11,5
60 2,0 2,0 3,5 5,0 6,0 7,5 9,0
65 2,0 1,5 2,5 3,5 4,5 5,5 6,5
70 2,0 1,5 2,0 2,5 2,5 3,0 3,5
75 2,0 1,0 1,0 1,0 1,0 1,0 1,0
T
aanvoer
(ge-
wenst)
[°C]
Ingestelde maximale branderwachttijd
[min]
35 40 45 50 55 60
30 29,0 33,0 37,0 41,0 45,0 49,5
35 25,5 29,5 33,0 36,5 40,5 44,0
40 22,5 26,0 29,0 32,0 35,5 38,5
45 19,5 22,5 25,0 27,5 30,5 33,0
50 16,5 18,5 21,0 23,5 25,5 28,0
55 13,5 15,0 17,0 19,0 20,5 22,5
60 10,5 11,5 13,0 14,5 15,5 17,0
65 7,0 8,0 9,0 10,0 11,0 11,5
70 4,0 4,5 5,0 5,5 6,0 6,5
75 1,0 1,0 1,0 1,0 1,0 1,0
8.6.2 Resterende branderwachttijd terugzetten
1.
Alternatief 1 / 2
Navigeer naar het Menu Reset wachttijd.
Op het display verschijnt de actuele brander-
wachttijd.
Druk op om de branderwachttijd terug te zetten.
1.
Alternatief 2 / 2
Druk op .
8.7 Onderhoudsinterval instellen
1. Navigeer naar het Menu Installateurniveau Dia-
gnosemenu D.084 Onderhoud over en bevestig
met .
2. Stel het onderhoudsinterval (bedrijfsuren) tot aan het
volgende onderhoud in en bevestig met .
Warmte-
vraag
Aantal
personen
Richtwaarden van de bran-
derbedrijfsuren tot aan de
volgende inspectie en het
volgende onderhoud in een
gemiddelde bedrijfstijd van
een jaar (afhankelijk van het
type installatie)
5,0 kW
1 2 1.050 h
2 3 1.150 h
10,0 kW
1 2 1.500 h
2 3 1.600 h
15,0 kW
2 3 1.800 h
3 4 1.900 h
20,0 kW
3 4 2.600 h
4 5 2.700 h
25,0 kW
3 4 2.800 h
4 6 2.900 h
> 27,0 kW
3 4 3.000 h
4 6 3.000 h
8.8 Pompvermogen instellen
Navigeer naar het Menu Installateurniveau Dia-
gnosemenu D.014 Pomptoerental gew. waarde en
bevestig met .
Stel het pompvermogen in en bevestig met .
Voorwaarden: Open verdeler geïnstalleerd
Schakel de toerentalregeling uit en stel het pompvermo-
gen op een vaste waarde in.
8.8.1 Restopvoerhoogte van de pomp
Pompkarakteristiek VHR NL 20 - 24/5-5
400
300
200
100
0
0 200 400 600 800 1000 1200 1600
Restopvoerhoogte
[
mbar
]
Debiet
[
l/h
]
1800
1400
100% PWM
85%
70%
60%
53%
Pompkarakteristiek VHR NL 25 - 30/5-5, VHR NL 25/5-5 S
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant ecoTEC plus VHR NL 35-5-5S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant ecoTEC plus VHR NL 35-5-5S in the language / languages: Dutch as an attachment in your email.

The manual is 5,82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vaillant ecoTEC plus VHR NL 35-5-5S

Vaillant ecoTEC plus VHR NL 35-5-5S User Manual - Dutch - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info