7Instructions for use ecoTEC
Hot water supply active
(ecoTEC plus combination boilers only)
Illuminated: Hot water demand
(ecoTEC system boilers only)
Illuminated: Heating of an indirect hot water
cylinder turned on
Flashing: Heating demand from the hot
water cylinder, burner on
Warmstart system active
(ecoTEC plus combination boilers only)
Illuminated: Warmstart turned on
Flashing: Warmstart demand, burner on
Internal pump is running
Gas valve is activated
Flame with cross:
Boiler is at lock out and will display fault code
Flame without cross:
Normal burner operation
4.2 Overview of controls on ecoTEC pro
bar
iFP
1
11
10
9
8
7
3
2
4
5
6
Fig. 4.3 ecoTEC pro controls
1 Display indicating the current heating flow tempera-
ture, the pressure in the heating system or additional
information
2 Indicator lights to display the current operating mode
3 The i” information button
4 Built in control/timer (if fitted)
5 Pressure gauge displaying the pressure in the heat-
ing system
6 Main ON/OFF control
7+” button for moving forward in the display
8-” button for moving back in the display or for dis-
playing the pressure in the heating system
9 “Reset” button
10 Maximum radiator temperature control
11 Maximum hot water temperature control and warm-
start ON/OFF
Multifunctional display system
ecoTEC pro boiler has a multifunction display (1). When
the main ON/OFF control is in the “ON” position the dis-
play will normally show the system CH flow temperature
of water in the boiler circuit (45 °C in the example),
which confirms that the boiler is functioning correctly.
bar
iFP
1
4
2
3
Fig. 4.4 ecoTEC pro indicator lights
1 Display indicating flow temperature or the system
pressure or the relevent fault code.
2 Green warmstart indicator
Illuminated = Warmstart switched ON
Not illuminated = Warmstart is switched OFF and
there is no demand for hot water
Flashing = There is either a demand for hot water or
warmstart
3 Yellow indicator
Illuminated = Main burner ignited
4 Red indicator
Illuminated = Boiler is at lock out and will display
fault code
As long as this symbol appears in the display, a
heating flow temperature and hot water outlet
temperature is set by the vrnetDIALOG accesso-
ry, which means the appliance uses temperatu-
res other than those set using the controls (10)
and (11).
This condition can only be ended:
- using vrnetDIALOG or
- by a change in temperature at controllers (10)
or (11) of more than ±5 K.
This condition cannot be ended:
- with the "Reset" button (9) or
- by turning the appliance off or on.
Operation 4
7


Need help? Post your question in this forum.

Forumrules
1

Forum

vaillant-ecotec-plus-637

Reset search

  • Hi Paul is my name,
    My 637 system boiler is not showing any display on display just blank
    Can you help please Submitted on 16-1-2022 at 16:02

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant ecoTEC plus 637 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant ecoTEC plus 637 in the language / languages: English as an attachment in your email.

The manual is 3,24 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info