602548
59
Zoom out
Zoom in
Previous page
1/72
Next page
Troubleshooting 7
0020077994_02 auroTHERM exclusive Installation manual 59
7 Troubleshooting
7.1 Spare parts for repair
Procuring spare parts
If you require spare parts for servicing or repair work, use
only Vaillant genuine spare parts.
The original components of the unit were also certified as
part of the CE declaration of conformity. If you do not use
certified Vaillant genuine spare parts, this voids the CE con-
formity of the unit. We therefore strongly recommend that
you fit Vaillant genuine spare parts.
Replacement parts
Applies to: Great Britain
An overview of the available genuine Vaillant spare parts
can be obtained:
From your parts wholesaler
Alternatively contact Spares Technical
Enquiries on 01773 596615 or via email: technic-
alspares@groupservice.co.uk
7.2 Carrying out repairs
7.2.1 Replace leaking collectors
Danger!
Risk of burns and scalding!
In the event of solar radiation inside the
units, collectors can reach 300 °C.
Avoid working in direct sunlight.
Cover the collectors before starting
work.
You should preferably perform the work
in the morning.
Wear suitable safety gloves.
1. Put the solar plant temporarily out of operation
( Page 61).
2. Replace the leaking collectors.
3. Start up the solar plant again as described in the oper-
ating system instructions.
7.2.2 Disposing of defective collectors
Your Vaillant collector consists largely of recyclable materi-
als.
The Vaillant collector must not be disposed of with normal
household waste.
Observe the applicable regulations.
Dispose of defective Vaillant collectors properly.
7.2.3 Sealing leaking connections
Danger!
Risk of burns and scalding!
In the event of solar radiation inside the
units, collectors can reach 300 °C.
Avoid working in direct sunlight.
Cover the collectors before starting
work.
You should preferably perform the work
in the morning.
Wear suitable safety gloves.
1. Put the solar plant temporarily out of operation
( Page 61).
2. Seal the leaking connections.
3. Start up the solar plant again as described in the oper-
ating system instructions.
7.2.4 Replacing defective pipe insulations
1. Put the solar plant temporarily out of operation
( Page 61).
2. To avoid heat losses, replace any defective pipe insula-
tions.
3. Start up the solar plant again as described in the oper-
ating system instructions.
7.2.5 Disposing of defective pipe insulations
The pipe insulations consist largely of recyclable materials.
The pipe insulations must not be disposed of with normal
household waste.
Observe the applicable regulations.
Dispose of the defective pipe insulations properly.
7.2.6 Replacing defective tubes
Danger!
Risk of injury caused by damaged va-
cuum tubes and sharp-edged compon-
ents.
Shards and sharp-edged components may
lead to cuts.
Wear suitable safety gloves.
59


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant auroTHERM exclusive VTK 570-2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant auroTHERM exclusive VTK 570-2 in the language / languages: English as an attachment in your email.

The manual is 9,54 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vaillant auroTHERM exclusive VTK 570-2

Vaillant auroTHERM exclusive VTK 570-2 Installation Guide - Dutch - 60 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info