602548
42
Zoom out
Zoom in
Previous page
1/72
Next page
5 Flat roof fitting and installation
42 Installation manual auroTHERM exclusive 0020077994_02
Vertical collector position
Installation angle 30°
Weights/rack [kg]
L
1
L
2
To secure against sliding and
lifting
To secure only against lifting
(if secured/anchored against
sliding)
Basic wind speed [km/h] Position
Building height Building height
up to 10
m
10-18 m 18-25 m up to 10
m
10-18 m 18-25 m
up to 72 Inland
L
L
301
167
378
213
429
244
44
167
40
213
70
244
up to 72 Coast and islands
L
L
413
234
487
279
534
307
67
234
81
279
90
307
up to 81 Inland
L
L
357
201
469
268
544
313
56
201
78
268
92
313
up to 81 Coast and islands
L
L
527
303
621
359
680
395
89
303
108
359
119
395
up to 90 Inland
L
L
469
268
581
335
656
380
78
268
100
335
115
380
up to 90 Coast and islands
L
L
619
358
731
425
806
470
107
358
129
425
144
470
up to 99 Inland
L
L
581
335
694
403
806
470
100
335
122
403
144
470
up to 99 Coast and islands
L
L
768
448
881
515
955
560
137
448
159
515
174
560
up to 108 Inland
L
L
694
403
843
492
955
560
122
403
152
492
174
560
up to 108 Coast and islands
L
L
918
537
1030
605
1143
672
166
537
188
605
211
672
42


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant auroTHERM exclusive VTK 570-2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant auroTHERM exclusive VTK 570-2 in the language / languages: English as an attachment in your email.

The manual is 9,54 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vaillant auroTHERM exclusive VTK 570-2

Vaillant auroTHERM exclusive VTK 570-2 Installation Guide - Dutch - 60 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info