4 On-roof fitting and installation
28 Installation manual auroTHERM exclusive 0020077994_02
Tightening the clamping ring connection
Caution.
Risk of damage to the collectors as a
result of improper installation.
If the hydraulic connections are not in-
stalled properly, the stainless steel tubes
inside the collector may become damaged.
When tightening the clamping ring con-
nection, hold a second spanner against
it.
20. Screw the two cap nuts securely onto the double nipple.
21. Tighten the clamping elements of the lower mounting
rail.
Working materials
SW 13 spanner
Completing collector rows
22. Install an additional collector. ( Page 27)
23. Fit the connectors. ( Page 27)
24. Tighten the clamping ring on the connection for both
collectors. ( Page 28)
Positioning the top mounting rails
1
25. Slide the upper mounting rails until they are flush with
the collectors.
26. Ensure that the clamping block (1) of the clamping ele-
ments lies over the collector rails.
27. Tighten the clamping elements of the top mounting
rails.
Working materials
SW 13 spanner
Positioning the central mounting rail
Conditions: Collector rows: 2 3
3
1
2
Slide the central mounting rail until it is flush with the
lower collector (3).
Ensure that the top clamping block of the clamping ele-
ment (2) is above the edge of the collector.
Secure the mounting rail (1) for the next collector row
to the clamping element.
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant auroTHERM exclusive VTK 570-2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant auroTHERM exclusive VTK 570-2 in the language / languages: English as an attachment in your email.

The manual is 9,54 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vaillant auroTHERM exclusive VTK 570-2

Vaillant auroTHERM exclusive VTK 570-2 Installation Guide - Dutch - 60 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info