602549
64
Zoom out
Zoom in
Previous page
1/72
Next page
10 Technical data
64 Installation manual auroTHERM exclusive 0020077994_02
10 Technical data
10.1 Technical data table
Unit VTK 570/2 VTK 1140/2
Number of tubes 6 12
η
0
(Aperture), DIN4757-4 or EN12975 % 64.2
c
1
with wind, or on aperture W/(m²k) 0.885
c
2
with wind, or on aperture W/(m²k²) 0.001
K
θ,trans
(50°), or on aperture 1
K
θ,long
(50°), or on aperture 0.9
Yield forecast (location: Würzburg, 5 m² aperture,
300 litre cylinder, 4 people)
kWh/m²a 586
Peak output per collector module W
peak
W 642 1278
Area-related heat capacity c kJ/(m²k) 8.3
Volume flow (per m² of collector surface) l/(m²h) 24
Minimum volume flow in the solar circuit l/h 180
Absolute pressure in the high vacuum bar 10
-5
mbar (= 10
-8
bar)
Alpha absorber absorption > 93.5% (see also ITW test report)
Epsilon absorber emission < 6% (see also ITW test report)
Grid dimensions (length x height x depth) m 0.7 x 1.65 x 0.11 1.39 x 1.65 x 0.11
Gross area m² 1.16 2.30
Aperture surface area m² 1.0 2.0
Absorber surface area m² 1.0 2.0
Collector capacity l 0.9 1.8
Weight kg 19 37
System overpressure, max. permissible bar 10
Shutdown temperature, max. °C 272
Connection width, flow/return mm 15
Material for the tube collector Al/1.4301/glass/silicone/PBT/EPDM/TE
Material for glass tubes Borosilicate 3.3
Material for selective absorber layer Aluminium nitride
Glass tubes (outer diameter/inner diameter/wall
thickness/tube length)
47 / 37 / 1.6 / 1500
Colour (plastic parts) Black
Thermal shock test ITW test
number
02COL282
Hail impact test in accordance with DIN EN 12975-2 TÜV test
number
435/142448
Type approval number 01-228-770
Max. wind load kg/Nm
2
1.2
Max. standard snow load kg/Nm
2
5
On-roof installation angle ° 15-75
Flat roof installation angle ° 30, 45, 60
64


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant auroTHERM exclusive VTK 1140-2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant auroTHERM exclusive VTK 1140-2 in the language / languages: English as an attachment in your email.

The manual is 9,54 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vaillant auroTHERM exclusive VTK 1140-2

Vaillant auroTHERM exclusive VTK 1140-2 Installation Guide - Dutch - 60 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info