Flat roof fitting and installation 5
0020077994_02 auroTHERM exclusive Installation manual 55
5.3 Completing and checking the installation
5.3.1 Checking installation
Use the following checklist to ensure that all work steps have been performed.
Operations Yes No Comments
Building statics taken into account during installation of
the system
Clearances from the roof edge complied with in accord-
ance with the specifications
Rack positioned in accordance with the dimensions spe-
cifications
All bolts securely tightened
(Installation and telescopic rail)
Adequate ballast weights used
(Only for floating installation)
Load weights adequately secured against slipping and
tilting
(Only for floating installation)
Rack anchored and bolts tightened
(Only for direct connection)
All hydraulic connections tightened
Hydraulic connections routed correctly
VR 11 collector sensor connected
(Only for systems WITH a collector sensor)
Collectors connected to lightning protection device
(Optionally for lightning protection device)
Pressure testing performed
(Ideally with compressed air)
All connections tight
Date Signature
All installation work has been
performed correctly. ˍ ˍ . ˍ ˍ . ˍ ˍ ˍ ˍ
55


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant auroTHERM exclusive VTK 1140-2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant auroTHERM exclusive VTK 1140-2 in the language / languages: English as an attachment in your email.

The manual is 9,54 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vaillant auroTHERM exclusive VTK 1140-2

Vaillant auroTHERM exclusive VTK 1140-2 Installation Guide - Dutch - 60 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info