Safety 2
0020077994_02 auroTHERM exclusive Installation manual 7
2.3.6 Risk of death due to inadequate fastening
of the collectors
Collectors can fall from their anchors if they are not prop-
erly fastened on the roof. Collectors falling from the roof
could cause life-threatening accidents.
Perform all work steps as described in this manual.
Observe all safety precautions described in this manual.
In addition, comply with all safety regulations that spe-
cifically apply in your region.
2.3.7 Risk of burns due to hot collector surfaces
In the event of solar radiation inside the units, collectors
can reach 300 °C. If you touch the collectors without pro-
tection, you could burn yourself.
Remove the sun protection film installed at the factory
only after the solar plant has been started up.
Avoid performing installation and maintenance work
under direct sunlight.
Cover the collectors before starting work.
You should preferably perform the work in the morning.
Wear suitable safety gloves.
2.3.8 Risk of injury due to breaking glass
The glass of the collectors may break due to mechanical
destruction or torsion.
Wear suitable safety gloves.
Wear suitable protective goggles.
2.3.9 Material damage caused by a high-pressure
cleaner
High-pressure cleaners may damage the collectors due to
the extremely high pressure.
Never clean the collectors with a high-pressure cleaner.
2.3.10 Material damage due to lightning
Lightning can damage the collector system.
Connect the collector system to a lightning protection
device in accordance with applicable regulations.
2.3.11 Frost damage due to water in the solar
circuit
Water residue in the collector may freeze in frosty condi-
tions and damage the collector.
Never fill or flush the collector with water.
Only fill and flush the collector with Vaillant ready-mixed
solar fluid.
Check the solar fluid regularly with an antifreeze tester.
2.3.12 Material damage due to an unsuitable tool
An unsuitable tool may damage the solar plant.
Only use a suitable tool.
In particular, only use the tool specified in the work steps
of this manual.
2.3.13 Risk of death from electric shock
Incorrect installation or a faulty power cable can result in a
supply voltage on the pipes, which can cause life-threaten-
ing injuries.
Secure earthing pipe clamps to the pipes.
Connect the earthing pipe clamps to a busbar using 16
mm² copper cable.
2.3.14 Material damage due to overvoltage
Overvoltage may damage the solar plant.
Earth the solar circuit to provide equipotential bonding
and overvoltage protection.
Secure earthing pipe clamps to the pipes.
Bond the earthing pipe clamps to a busbar using 16 mm²
copper cable.
2.3.15 Risk of death and material damage due to
contact corrosion
For roofs or façade sections made of metals more precious
than aluminium (e.g. copper roof), contact corrosion may
occur on the brackets. Collectors could fall and put persons
at risk.
Use suitable underlays to separate the metals.
2.3.16 Material damage due to snow falling from
roofs
If the collector field is installed below a sloping roof, then
snow falling from the roof may damage the collectors.
Install snow fences above the collectors as protection
against falling snow.
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant auroTHERM exclusive VTK 1140-2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant auroTHERM exclusive VTK 1140-2 in the language / languages: English as an attachment in your email.

The manual is 9,54 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vaillant auroTHERM exclusive VTK 1140-2

Vaillant auroTHERM exclusive VTK 1140-2 Installation Guide - Dutch - 60 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info