12 Operating instructions for auroSTOR 0020111120_02
8 Technical data
Unit VIH S GB 210/2 S VIH S GB 260/2 S VIH S GB 310/2 S
Total capacity litres 210 260 310
Actual capacity litres 209,4 254,4 297,2
Hot water capacity (upper coil) litres 104,8 142,0 144,2
Hot water capacity (solar coil) litres 203,3 246,1 271,1
Dedicated solar volume litres 104,6 112,4 153,0
Maximum supply pressure to pressure reducing valve MPa (bar) 1,2 (12)
Rated pressure of cylinder MPa (bar) 0,7 (7)
Maximum operating pressure of heating coil MPa (bar) 0,35 (3,5)
Maximum operating pressure of solar coil MPa (bar) 0,6 (6)
Operating pressure MPa (bar) 0,35 (3,5)
Pressure limiting valve MPa (bar) 0,35 (3,5)
Expansion relief valve MPa (bar) 0,6 (6)
Temperature and pressure relief valve °C,
MPa (bar)
90,
0,7 (7)
Charge pressure of hot water expansion vessel MPa (bar) 0,4 (4)
Maximum temperature of heating circuit °C 85
Maximum temperature of potable hot water °C 85
Maximum temperature of solar fluid °C 85
Standing heat loss kW/24 h 1,98 2,15 2,35
Heat up time according to EN 12897 mins 20 27 28
Recovery time (70% capacity) mins 15 20 21
Primary heat exchanger performance kW 16,7 16,5 16,0
Flow rate for primary heat exchanger performance l/min 23,3
Primary heat exchanger pressure drop mbar 79 78 79
Primary heat exchanger volume Liter 2,37
Primary heat exchanger surface area m
2
0,5
Heat up time according to EN 12897 (solar) min 32 40 49
Solar heat exchanger performance kW 19,7 19,5 17,2
Flow rate for solar heat exchanger output l/min 23,3
Solar heat exchanger pressure drop mbar 97 95 98
Solar heat exchanger volume Liter 2,94
Solar heat exchanger surface area m
2
0,62
Dimensions
Height mm 1593 1843 2153
Height with hot water draw off mm 1625 1875 2185
Topple measure mm 1680 1918 2217
Diameter mm 554,5
Depth mm 624
Net weight kg 40 43 50
Weight (full) kg 249 298 347
Connections
Cold water inlet 22 mm unprofiled pipe (crimp joints)
Hot water draw off 22 mm unprofiled pipe (crimp joints)
Balanced pressure cold water outlet 22 mm unprofiled pipe (crimp joints)
Secondary return 15 mm unprofiled pipe (crimp joints)
Primary heater flow 22 mm unprofiled pipe (crimp joints)
Primary heater return 22 mm unprofiled pipe (crimp joints)
Solar flow 22 mm unprofiled pipe (crimp joints)
Solar return 22 mm unprofiled pipe (crimp joints)
Primary heating circuit immersion sleeve size mm 8
Solar circuit immersion sleeve size mm 8
Tab. 8.1 Technical data for auroSTOR solar cylinder
8 Technical data
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant auroSTOR VIH S GB 260 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant auroSTOR VIH S GB 260 in the language / languages: English as an attachment in your email.

The manual is 0,61 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info