535156
37
Zoom out
Zoom in
Previous page
1/76
Next page
17Gebruiksaanwijzing en installatiehandleiding boilers uniSTOR, auroSTOR, geoSTOR 0020029429_02
10 Technische gegevens
10.1 Technische gegevens VIH S 300/400/500 en
VIH R 300/400/500
Eenheid
VIH S VIH R
VIH S 300 VIH S 400 VIH S 500 VIH R 300 VIH R 400 VIH R 500
Nominale boilerinhoud l 300 400 500 300 400 500
Daadwerkelijke boilerinhoud l 289 398 484 295 404 496
Max. werkdruk boiler bar 10 10 10 10 10 10
Max. werkdruk CV bar 10 10 10 10 10 10
Max. warmwatertemperatuur °C 85 85 85 85 85 85
Max. aanvoertemperatuur verwar- °C 110 110 110 110 110 110
Energieverlies standby kWh/d 1,9 2,1 2,3 1,8 2,0 2,2
CV-warmtewisselaar:
Verwarmingsoppervlak van de warmte- m
2
0,7 0,7 1,0 1,6 1,5 2,1
Inhoud verwarmingswater van de l 4,7 4,5 6,6 10,7 9,9 14,2
Drukverlies in de warmtewisselaar bij
max. verwarmingswatervraag mbar 11 11 16 75 75 125
Verwarmingsmiddelstroom l/h 900 900 1250 2000 2000 2700
Uitgangsvermogen warm water bij
45/10 °C
1)
l/10 min 195 190 215 462 519 591
Continuvermogen warm water bij ver-
warmingswatertemperatuur 85/65 °C
2)
kW 20 21 29 46 46 62
Continuvermogen warm water bij ver-
warmingswatertemperatuur 85/65 °C
2)
l/h 491 516 712 1130 130 1523
Vermogensgetal
1)
N
L
2,0 3,5 4,7 11,0 15,0 19,0
Zonnewarmtewisselaar:
Verwarmingsoppervlak van de warmte-
wisselaar
m
2
1,6 1,5 2,1
Inhoud verwarmingswater van de l 10,7 9,9 14,2
Drukverlies in de warmtewisselaar bij
werking op zonne-energie met collec-
torvloeistof mbar <10 <10 <10
Collectorvloeistofstroom l/h 200 300 500
Aansluitingen:
Koudwater- en warmwateraansluiting schroef- R1 R1 R1 R1 R1 R1
Circulatie-aansluiting schroef- R
3
/
4
R
3
/
4
R
3
/
4
R
3
/
4
R
3
/
4
R
3
/
4
Aanvoer- en retouraansluiting schroef- R1 R1 R1 R1 R1 R1
Boilerafmetingen:
Breedte met mantel mm 660 810 810 660 810 810
Diepte met mantel mm 725 875 875 725 875 875
Hoogte mm 1775 1470 1775 1775 1470 1775
Buitendiameter reservoir zonder isola-
tie mm 500 650 650 500 650 650
Gewicht (incl. verpakking en isolatie) kg 150 169 198 125 145 165
Gewicht gereed voor gebruik gevuld kg 439 567 682 420 549 661
Tabel 10.1 Technische gegevens VIH S 300/400/500 en
VIH R 300/400/500
1)
conform DIN 4708, deel 3
2)
temperatuurverschil warm- koud water: 35 K
Technische gegevens 10
NL, BENL
37


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant auroSTOR VIH R 400 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant auroSTOR VIH R 400 in the language / languages: German, Dutch, French, Italian as an attachment in your email.

The manual is 4,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vaillant auroSTOR VIH R 400

Vaillant auroSTOR VIH R 400 User Manual - Dutch - 19 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info