143Installation instructions auroMATIC 620 0020094404_00 controller
Glossary
Switch-on room temperature:
The usage of the room sensor in the remote control
devices (RCD) or operating unit (in this case the opera-
ting unit should be inserted in the VR 55 mounting box
(accessory)) can be parameterised for each heating cir-
cuit. Factory (setting)
The switch-on room temperature is used to include the
current room temperature in a reference room in the
calculation of the flow temperature. The room tempera-
ture sensor of the assigned RCD is used if the function
is active. The value of the operating unit is used if no
RCD is available. (As a result it is possible to use the
operating unit also in a reference room for this function
by means of a wall mount.)
Target flow temperature
Represents the inlet temperature in a heating circuit
calculated by the controller on the basis of the pre-set
parameters.
Temperature correction for actual room temperature
You can shift the displayed value for the room tempera-
ture up or down within a range of +/–3 °C as required.
Temperature fault detection
With this function it is possible to detect faults regar-
ding the setting or layout in a heating circuit. If the sti-
pulated target temperature is still not reached after a
longer time period (parameterisation: OFF, between 1
and 12 hours), an error message appears for the circuit
in question.
Default setting: Off
Test mode
In test mode you can test and actuate every single sen-
sor, each pump and each mixer per heating circuit sepa-
rately.
3. Difference Control
Operation:
if TD2 > TD1 + switch-on difference (Menu C5), then
output MA is activated
if TD2 < TD1 + switch-on difference (Menu C5), then
output MA is switched off again
In the hydraulic plans 1-4, the 3rd differential control
serves as heating support.
In all other plans the 3rd differential control is not
available.
201


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant Auromatic 620 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant Auromatic 620 in the language / languages: English as an attachment in your email.

The manual is 6,37 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vaillant Auromatic 620

Vaillant Auromatic 620 User Manual - German - 52 pages

Vaillant Auromatic 620 User Manual - Dutch - 204 pages

Vaillant Auromatic 620 User Manual - French - 204 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info