535173
17
Zoom out
Zoom in
Previous page
1/24
Next page
Gasinstelling
Bedienings- en installatiehandleiding atmoSTOR 0020148317_00 17
6
6.4 Aardgasinstelling controleren
( volumetrische methode)
> Tap bij een opgewarmde atmoSTOR VGH warm water om
de boilertemperatuur te verlagen.
> Neem het toestel in gebruik.
> Zet de temperatuurkeuzeknop op de stand "E"
(¬ afb. 6.2, pos. 5).
> Stel alle andere gastoestellen buiten bedrijf die via
dezelfde gasteller aangesloten zijn.
> Lees de doorstroming in l/min aan de gasteller af
(meting het best met een chronometer).
1e gasfamilie: aardgas van de groep 2 E+; af fabriek ingesteld voor W
s
= 50,72 MJ/m
3
, H
i
= 34,02 MJ/m
3
atmoSTOR
Nominale
warmtebe-
lasting
Hoofdbranderverstuiver
Ontstekingsbran-
derverstuiver
Gasdoorstro-
ming
Verstuiverdruk
[kW] Aantal Aanduiding* Aanduiding* [l/min] [hPa/mbar]
VGH 130/5 XZU 7,0 3 138 25 12,5 19,8
VGH 160/5 XZU 8,0 3 145 25 14,2 19,8
VGH 190/5 XZU 9,0 3 155 25 16,0 19,8
VGH 220/5 XZU 9,0 3 155 25 16,0 19,8
6.2 Gasfamilies
* De verstuivers zijn met de in deze tabellen vermelde waarden
gestempeld. De aanduiding komt overeen met de boringsdiame-
ter vermenigvuldigd met 100.
> Vergelijk de afgelezen gasdoostromingshoeveelheid met
de gewenste waarden (¬ tab. 6.2).
Bij afwijkingen van minder dan 10 % zijn er geen maatre-
gelen vereist.
Als de afwijkingen groter dan 10 % zijn, controleer dan de
voorsmoorkleppen en de branderverstuiver (¬ tab. 6.2).
> Win het advies van de fabrieksklantendienst in als u bij
deze controle geen onregelmatigheid vaststelt en er na
samenspraak met de bevoegde gasmaatschappij geen
storing in de gasvoorziening is.
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant atmoSTOR VGH at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant atmoSTOR VGH in the language / languages: Dutch as an attachment in your email.

The manual is 1,35 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info