602540
10
Zoom out
Zoom in
Previous page
1/52
Next page
5 Assembly and installation
10 Installation instructions aroTHERM 0020147164_04
When transporting the product, two
people should lift it.
Observe the product weight stated in the
technical data.
When transporting heavy loads, observe
the applicable directives and regulations.
Caution.
Risk of material damage due to incorrect
transportation.
Regardless of the mode of transport, the heat
pump must never be tilted by more than 45°.
Otherwise, this may lead to malfunctions in
the coolant circuit during subsequent opera-
tion. In the worst case scenario, this may lead
to a fault in the whole system.
During transport, do not tilt the heat pump
by any more than the maximum angle of
45°.
1. Use the transportation belt to carry the product to the
final installation site.
2. Only lift the product from the back and side where the
hydraulic connections are located.
3. When transporting the product using a hand truck, se-
cure the product using a belt.
4. In order to avoid scratches and damage, protect the
sides of the product that come into contact with the
hand truck.
5.1.1.2 Unpacking the product
13mm
1
2
3
4
B
A
D
E
C
1. Remove the accessory (2).
2. Remove the documentation supplied (1).
3. Remove the transport belt (4).
4. Carefully remove the packaging and padding without
damaging the product (3).
5. Remove the screws from the pallet at the front and rear
of the product.
5.1.1.3 Checking the scope of delivery
Check the contents of the packaging units
Quant-
ity
Description
1 Condensate discharge
1 Bag with seals
4 Vibration-isolating feet
1 Purge hose
5.1.2 Complying with clearances and installation
clearances
5.1.2.1 Unit dimensions and connection
dimensions
120
120
74 0
980
408
840*
386
VWL 55/2 A 230 V
386
11
* Size increases by 45 mm
when using the vibration
dampers supplied.
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant aroTHERM VWL 85-2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant aroTHERM VWL 85-2 in the language / languages: English as an attachment in your email.

The manual is 3,09 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vaillant aroTHERM VWL 85-2

Vaillant aroTHERM VWL 85-2 User Manual - English - 28 pages

Vaillant aroTHERM VWL 85-2 User Manual - German - 24 pages

Vaillant aroTHERM VWL 85-2 User Manual - Dutch - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info