602542
47
Zoom out
Zoom in
Previous page
1/52
Next page
Appendix
0020147164_04 aroTHERM Installation instructions 47
VWL 55/2 A
230 V
VWL 85/2 A
230 V
VWL 115/2 A
230 V
VWL 155/2 A
230 V
Nominal volume flow
rate, max. volume flow
rate
860 l/h 1,400 l/h 1,900 l/h 2,590 l/h
Hydraulic pressure differ-
ence
640 mbar 450 mbar 300 mbar 370 mbar
Technical data Coolant circuit
VWL 55/2 A
230 V
VWL 85/2 A
230 V
VWL 115/2 A
230 V
VWL 155/2 A
230 V
Coolant type
R410A R410A R410A R410A
Coolant contents
1.80 kg 1.95 kg 3.53 kg 4.40 kg
Maximum permissible
operating overpressure
4.15 MPa
(41.50 bar)
4.15 MPa
(41.50 bar)
4.15 MPa
(41.50 bar)
4.15 MPa
(41.50 bar)
Compressor type
Rotary piston Rotary piston Rotary piston Rotary piston
Oil type
Specific
polyvinyl ether
(PVE)
Specific
polyvinyl ether
(PVE)
Specific
polyvinyl ether
(PVE)
Specific
polyvinyl ether
(PVE)
Coolant circuit control
system
Electronic Electronic Electronic Electronic
Technical data Heat pump system performance data
VWL 55/2 A
230 V
VWL 85/2 A
230 V
VWL 115/2 A
230 V
VWL 155/2 A
230 V
Heating output A-7/W35
4.90 kW 6.70 kW 7.90 kW 11.80 kW
A-7/W35 output figure/EN
14511 coefficient of per-
formance
2.40 2.80 2.50 2.60
A7/W35 heating output
4.70 kW 8.10 kW 10.50 kW 14.60 kW
A7/W35 output figure/EN
14511 coefficient of per-
formance
4.70 4.80 4.20 4.50
Power consumption ef-
fective at A7/W35
1.10 kW 1.80 kW 2.50 kW 3.40 kW
Input current at A7/W35
4.80 A 7.80 A 10.90 A 14.80 A
A7/W45 heating output
4.40 kW 7.80 kW 10.20 kW 13.40 kW
A7/W45 output figure/EN
14511 coefficient of per-
formance
3.40 3.80 3.40 3.40
Power consumption ef-
fective at A7/W45
1.30 kW 2.10 kW 3.00 kW 4.10 kW
Input current at A7/W45
5.70 A 9.10 A 13.00 A 17.80 A
A7/W55 heating output
4.20 kW 7.00 kW 9.80 kW 11.20 kW
A7/W55 output figure/EN
14511 coefficient of per-
formance
2.70 3.00 2.90 2.30
Power consumption ef-
fective at A7/W55
1.60 kW 2.40 kW 3.50 kW 5.00 kW
Input current at A7/W55
7.00 A 10.40 A 15.20 A 21.70 A
47


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant aroTHERM VWL 55-2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant aroTHERM VWL 55-2 in the language / languages: English as an attachment in your email.

The manual is 3,09 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vaillant aroTHERM VWL 55-2

Vaillant aroTHERM VWL 55-2 User Manual - German - 24 pages

Vaillant aroTHERM VWL 55-2 User Manual - Dutch - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info