602541
39
Zoom out
Zoom in
Previous page
1/52
Next page
Appendix
0020147164_04 aroTHERM Installation instructions 39
KOL1-
P
Solar pump for collector field 1
SP1 Cylinder temperature sensor
SP2 Cylinder temperature sensor (solar cylinder)
VF1 Flow temperature sensor 1
ZP Circulation pump
C.3 Wiring diagram 10 B
UV1
MA2
MA1
230 V~
230 V~
ME
EVU
2
1
SP1
DCF/AF
VF1
+
-
BUS
ZH
230 V~
2
1
PE
1
2
N
PE
Auf
Zu
N
PE
N
PE
N
PE
N
PE
N
L
L
L
L
L1 L2
L3
PE N N
1
2
400 V~
16
DCF 0 AF
VRC 470
13e
13b
230 V~
BUS
2
1
VF2
VR 61
VR 81
13a
91
VWZ AI VWL X/2
UV1
VF1
94
VWZ MEH 60
230 V~
VF2
M
UV1
SP1
HK-P
92
VWZ MWT 150
VWL x5/2 A 230 V
-
+
EBUS
FLOOR HX7
X4
230 V~
L
N
X9
X2
3
1
2
400 V~
L3
N
L2
L1
X2
VWL x5/2 A 400 V
AF
DCF
T0
3,3 V / 5 V /
24 V
2
1
2
1
28 (HK2-P)
19
nc
ZP
M
28 (HK1-P)
19
nc
M
HK1-P
230 V~
L
N
PE
L
N
PE
L
N
PE
HK2
HK2-P
LP/ZP
Auf
Zu
N
PE
L
N
PE
230 V~
3 Heat pump
13a Remote control unit
13b Mixer module
13e System controller
39


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant aroTHERM VWL 115-2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant aroTHERM VWL 115-2 in the language / languages: English as an attachment in your email.

The manual is 3,09 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vaillant aroTHERM VWL 115-2

Vaillant aroTHERM VWL 115-2 User Manual - English - 28 pages

Vaillant aroTHERM VWL 115-2 User Manual - German - 24 pages

Vaillant aroTHERM VWL 115-2 User Manual - Dutch - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info