36 Installations- und Wartungsanleitung aroTHERM 0020243714_00
C.2 Verbindungsschaltplan, Teil 2
X11
X100 / X106
X27
X25
S20
S21
BUS
5
6
3
4
1
2
L
N
M
p
X21
X23
X22
1
7
8
2
918
17
16
15
14
13
12
11
10
3
4
5
6
1
2
6
7
8
9
10
3
4
5
12
X28
1
2
7
8
9
11
10
12
3
4
5
6
1
7
8
2
919
20
18
17
16
15
14
13
12
11
10
3
4
5
6
X16
3
1
2
L
N
X13
L
N
X15
3
4
1
2
L
L
N
X14
L
L
N
X1
L
N
X24
6
4
3
2
1
5
7
8
9
12
11
10
13
14
15
16
3
1
2
3
1
2
3
4
1
2
3
4
1
2
p
˽
˽
˽
M
˽
31
42
2
3
4
15
16
14
13
1
5
6
7
12
11
10
9
8
17
18
1 Leiterplatte HMU
2 Ansteuerung für Ventilator 2 (nur bei Produkt
VWL 105/5 und VWL 125/5)
3 Verbindung zur Leiterplatte INSTALLER BOARD
4 Kurbelwannenheizung
5 4-Wege-Umschaltventil
6 Kondensatwannenheizung
7 Verbindung zur Leiterplatte INSTALLER BOARD
8 Temperatursensor, am Lufteintritt
9 Ansteuerung für Ventilator 1
10 Temperatursensor, hinter dem Kompressor
11 Temperatursensor, vor dem Kompressor
12 Druckwächter
13 Temperaturwächter
14 Drucksensor
15 Elektronisches Expansionsventil
16 Ansteuerung für Baugruppe INVERTER
17 Steckplatz für Kodierwiderstand für Kühlbetrieb
18 Bereich der Sicherheitskleinspannung (SELV)
38


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant aroTHERM split VWL 125-5 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant aroTHERM split VWL 125-5 in the language / languages: German, Dutch, French, Italian as an attachment in your email.

The manual is 5,22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info