3.5 Status display
(For maintenance and service work performed by your
installer or service agent)
The status displays are activated by pressing the "i"
button (1). The current status code, e.g. "S.34" for the
frost protection mode, is shown on the display (2).
Pressing the "i" button again will switch you back to the
normal mode.
The "+" and "-" buttons will only be used by your
installer or service agent during service and
maintenance work.
Fig. 3.10: Status displays
Table 3.1: Status displays (A complete overview of the status
codes can be found in the installation instructions).
* Heating operation, ** Hot water operation
2
1
VRC-VC
C
o
0
I
C
o
9
Operation 3
Instructions for use VUI 362-7 9
3.6 Resetting the appliance
When a hot water tap or the central heating system
requires heat, the boiler automatically ignites and starts
to operate. If the automatic ignition is not successful
within 10 seconds, then the boiler does not go into
operation and switches to "Lock out".
This is indicated visually by the crossed out flame in the
display and the displaying of fault code "F.28" or "F.29"
(flame extinguished during operation). A new attempt to
ignite the flame can then only be performed after
pressing the "Reset" button.
Press the "Reset" button (2) and hold for approx. 1
second.
Warning!
If the boiler still shuts off after a third attempt,
then please consult your installer or Vaillant
Service Solutions.
The boiler also switches to "Fault" when there is not
enough water in the system. This fault is indicated by
fault codes "F 22", "F.23" or "F.24". The boiler must only
be placed back in operation after the heating system has
been properly refilled with water.
In the unlikely event of any other fault developing, which
prevents the boiler from operating, the display will also
show other fault codes. If a fault code is displayed
please contact your installer or Vaillant Service
Solutions.
Note!
If contacting Vaillant Service Solutions please
remember to quote the fault code, as this will
help to pinpoint the fault.
Fig. 3.11: Reset
C
o
0
I
C
o
VRC-VC
Display Meaning
S.00* No heating demand
S.02* Pump running
S.03* Ignition sequence
S.04* Burner ignited
S.05* Fan and water pump over run
S.07* Water pump over run
S.08* Anti cycling mode (after heating operation)
S.10** Hot water demand
S.20** Tank cycle mode active
S.28** Anti cycling mode (after tank filling)
S.34* Frost protection mode active
834641_12GB_032005.qxd 09.03.2005 16:42 Uhr Seite 9
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant aquaPLUS VUI at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant aquaPLUS VUI in the language / languages: English as an attachment in your email.

The manual is 0,85 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vaillant aquaPLUS VUI

Vaillant aquaPLUS VUI Installation Guide - English - 56 pages

Vaillant aquaPLUS VUI User Manual - English, German - 40 pages

Vaillant aquaPLUS VUI Manual - Dutch - 2 pages

Vaillant aquaPLUS VUI User Manual - Dutch, French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info