Diagrams 11
Instructions for installation and servicing aquaPLUS VUI 362-7 49
11 Diagrams
11.1 Functional Flow diagram: aquaPLUS VUI 362-7
POWER SUPPLY
F2A
L
2
N
1
MAIN SWITCH
MAIN
TRANSFORMER
230V
20V
AIR
PRESSURE
SWITCH
FAN
PUMP
NTC FLOW
TEMPERATURE
SENSOR
FLAME
SENSOR
GAS
VALV E
DHW
Aqua
Sensor
F1,25A
NTC RETURN
TEMPERATURE
SENSOR
Burner lock out
indicator
Hot water
demand indicator
Ignition indicator
MAIN SWITCHBOARD
IGNITION
ELECTRODES
Legend
b blue
br brown
y/g yellow/green
r red
p pink
or orange
t transparent
bl black
gr grey
w white
gr
b
br
y/g
bbr
y/g
br
t
w
p
t
br
br
r
b
br
y/g
gr
p
p
r
CONTROL BOX
DIVERTER
VALV E
bl
bl
bl
bl
NTC
TANK
TEMPERATURE
SENSOR
or
plug in
connector
plus / minus buttons
reset button
info button
Hot water
demand indicator
vi violet
NTC
DHW
TEMPERATURE
SENSOR
vi
DHW
PUMP
b br y/g
Central heating
demand indicator
r
bl
b
gr
Fig. 11.1: Functional Flow diagram VUI 362-7
49


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant aquaPLUS VUI at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant aquaPLUS VUI in the language / languages: English as an attachment in your email.

The manual is 3,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vaillant aquaPLUS VUI

Vaillant aquaPLUS VUI User Manual - English - 12 pages

Vaillant aquaPLUS VUI User Manual - English, German - 40 pages

Vaillant aquaPLUS VUI Manual - Dutch - 2 pages

Vaillant aquaPLUS VUI User Manual - Dutch, French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info