5 Boiler Installation Sequence 5
Instructions for installation and servicing aquaPLUS VUI 362-716
5.7 Gas supply
Connect the 15 mm compression gas service cock (1)
and 22 mm copper outlet tail (3) as supplied with the
appliance (2) and tighten.
Connect a gas supply pipe of not less than 22 mm
diameter to the copper tail.
Tighten all connections.
(Ensure the gas supply pipework is adequately sized
such that a 20 mbar gas pressure is available at the
boiler inlet at full flow rate).
Fig. 5.6: Fitting the gas connection aquaPLUS
I
0
3
1
2
5.8 Cold water mains inlet and hot water outlet
Flush all foreign matter from the mains supply before
connecting to the boiler.
Connect the cold water service valve (1) to the cold
inlet water connection (3) of the appliance with the
washer (2) provided and tighten.
Connect the 15 mm cold water inlet pipe copper tail
(4) to the cold water service valve (1) and tighten.
Connect the 15 mm hot water outlet copper tail (6) to
the hot water outlet connection of the appliance (8)
with the washer provided (7) and tighten.
Note: The hot water outlet union nut is packed in
with the PRV fitting pack.
Connect the cold water service pipe and hot water
outlet pipework to the copper tails.
Fig. 5.7: Fitting the hot and cold water connections aquaPLUS
I
0
1
2
3
4
6
7
8
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant aquaPLUS VUI at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant aquaPLUS VUI in the language / languages: English as an attachment in your email.

The manual is 3,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vaillant aquaPLUS VUI

Vaillant aquaPLUS VUI User Manual - English - 12 pages

Vaillant aquaPLUS VUI User Manual - English, German - 40 pages

Vaillant aquaPLUS VUI Manual - Dutch - 2 pages

Vaillant aquaPLUS VUI User Manual - Dutch, French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info