Installationsanvisning allSTOR VPA 0020030713_0216
9 Tekniska data
Beteckning Enhet VPA 500 VPA 750 VPA 1000 VPA 1500
Total höjd mm 1840 2010 2270 2290
Bredd utan isolering mm 650 750 790 1000
Bredd med isolering mm 850 950 990 1200
Lutande mått (utan isolering) mm 1780 1975 2240 2270
Vikt
– tom, med förpackning
– tom, utan förpackning
– monterad och fylld
kg
kg
kg
210
190
690
252
227
977
276
249
1249
304
276
1776
Tankvolym
– tappvatten
– värmevatten
l
l
40
500
48
750
48
1000
56
1500
Max. tillåtet arbetstryck
– tappvattentank
– värmeväxlare, värmevatten
MPa/bar
MPa/bar
0,6/6
0,3/3
0,6/6
0,3/3
0,6/6
0,3/3
0,6/6
0,3/3
Max. tillåten temperatur °C 95 95 95 95
Anslutning värmekrets Rp 1 1/4" Rp 1 1/4" Rp 1 1/4" Rp 1 1/2"
Fläns värmeväxlare solvärmekrets Dn200, 12 x M12 Dn200, 12 x M12 Dn200, 12 x M12 Dn200, 12 x M12
Muff elpatron
1)
Rp 2" Rp 2" Rp 2" Rp 2"
Anslutning kall- och varmvatten Rp 1" Rp 1" Rp 1" Rp 1"
Anslutning tömningsventil Rp 1 1/4" Rp 1 1/4" Rp 1 1/4" Rp 1 1/2"
Energiförlust beredskap kW/24 h < 3,38 < 3,58 < 3,74 < 3,97
Tab. 9.1 Tekniska data
1)
Av konstruktionstekniska skäl fär endast de elpatroner
användas, som anges i den här anvisningen.
10 Information för den driftansvarige
10.1 Skötsel
Rengör multifunktionsberedaren med en fuktig trasa
och lite tvållösning. Använd inte skur- eller rengörings-
medel, som kan skada isoleringen.
10.2 Frostskydd
a
Observera!
Frostrisk!
Multifunktionsberedaren måste tömmas helt
om den ska stå oanvänd under längre tid i ett
oeldat utrymme (t.ex. under vintersemestern).
Låt en auktoriserad installatör genomföra
tömningen.
10.3 Underhåll
Liksom för hela systemet gäller även för multifunktions-
beredaren VPA att regelbundet underhåll av en auktori-
serad installatör skapar de bästa förutsättningarna för
hög driftsäkerhet, tillförlitlighet och lång livslängd.
Försök aldrig själv utföra underhåll på systemet. Låt en
auktoriserad installatör utföra arbetena.
9 Tekniska data
10 Information för den driftansvarige
86


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant allSTOR VPA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant allSTOR VPA in the language / languages: German, Danish, French, Italian as an attachment in your email.

The manual is 1,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info