550299
6
Zoom out
Zoom in
Previous page
1/14
Next page
On the main display screen the gas content
eld shows the O2/He format for each gas
when Tec SW is enabled.
While diving, when pressing long the 
button, the gas summary is shown. The
second column shows the pressure when
transmitters are used. The transmitter
communicates the pressure signal only
from the actively used gas. When the gas is
not used within 5 minutes, the transmitter
goes to a power save mode and Galileo
shows “--” in the pressure eld.
F
Note:
Futuregenerationtransmittersforthe
Galileo will however remain active
when pressurized, even when gas is
notused.
The third column shows the content of the
gas in format O2/He in case of Trimix or
xxx% if the gas is nitrox or pure oxygen.
Short press , the prole display is
shown. The dark color indicates the part
that is done and the dashed line shows the
ascent prole. Normally predicted gas
changes are shown on ascent prole, but in
the Tec SW there can be additional steps
depending on gas mix enabling (Tank x, on/
off). The following screen shows the tissue
saturation at that point.
The tissue saturation screen shows 16 bars
where the standard Galileo SW had 8 bars.
When the previously shown dive proceeds
to the ascent phase the decompression is
still increasing, as seen from the table
information on the right side. The fast
compartments begin off gassing and the
effect is shown in the saturation bar
diagram below.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for UWATEC Galileo Trimix software at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of UWATEC Galileo Trimix software in the language / languages: English as an attachment in your email.

The manual is 0,5 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of UWATEC Galileo Trimix software

UWATEC Galileo Trimix software User Manual - German - 14 pages

UWATEC Galileo Trimix software User Manual - Dutch - 14 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info