550357
23
Zoom out
Zoom in
Previous page
1/62
Next page
2. Menus, settings and functions
21
English
In addition:
- For the CLASSIC confi guration, the
value of the set depth replaces the
max depth indication and is shown
in inverted colors (white on black
background). This will remain so for as
long as the diver stays deeper than the
set depth.
- For the LIGHT confi guration, the current
depth is displayed in inverted colors
(white on a black background) and will
remain so until the diver ascends above
the set depth. In addition, after the text
message extinguishes, in the lower
left corner the value of the set depth
is shown in inverted colors. Alternate
information is still available as described
in section 3.3.3, but after 5 seconds the
inverted set depth is shown again. This
will remain so for as long as the diver
stays deeper than the set depth.
- For the FULL confi guration, the value of
the set depth replaces the max depth
indication and is shown in inverted
colors (white on black background).
This will remain so until the diver
ascends above the set depth.
2.6.2 CNS O
2
= 75% (default: OFF)
Galileo tracks your oxygen uptake during
the dive via the CNS O
2
clock. This can be
monitored via the oxygen bar on the left
side of the screen (CLASSIC and FULL
display confi gurations) and also via the
CNS O
2
indication (CLASSIC, LIGHT and
FULL). Galileo triggers an alarm when the
value reaches 100%; in addition you can
choose to have a warning triggered when
the CNS O
2
clock reaches 75%.
During the dive, if the calculated CNS O
2
value reaches 75% and the warning is
set to either VISUAL or BOTH, Galileo
will show the message CNS O
2
= 75%
for 12 seconds in place of the no-stop or
decompression information.
In addition:
- For the CLASSIC confi guration, the
value of CNS O
2
is shown, in inverted
colors (white on black background). This
will remain so for as long as the CNS O
2
value is higher than 75%.
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for UWATEC Galileo Terra at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of UWATEC Galileo Terra in the language / languages: English as an attachment in your email.

The manual is 1,8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of UWATEC Galileo Terra

UWATEC Galileo Terra User Manual - German - 66 pages

UWATEC Galileo Terra User Manual - Dutch - 64 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info