2. Menus, settings and functions
15
English
!
WARNING
- Diving with Nitrox may only be attempted
by experienced divers after proper training
from an internationally recognized agency.
- Before every dive and after changing the
tank, you must make sure that the set
oxygen concentration in Galileo corresponds
to the oxygen concentration in the tank.
Setting the wrong oxygen concentration can
lead to serious injury or death.
2.3 Dive settings
2.3.1 MB level (default: L0)
Upon entering this menu, the currently
active MB level is displayed. Using the +
and - buttons you can change between
levels, from L0 (baseline algorithm) to L5
(highest level of added conservatism).
2.3.2 Gauge mode (default: OFF)
Upon entering this menu, the words ON
or OFF will be highlighted on the screen,
indicating whether the gauge mode is
active (ON) or inactive (OFF). If the gauge
mode is inactive, Galileo will function as
a dive computer. If the gauge mode is
active, Galileo does not carry out any
decompression calculation and does not
provide any warnings or alarms.
See section 3.7 for restrictions on setting
Galileo from computer mode to gauge
mode and vice versa.
2.3.3 Safety stop timer (default:
automatic, 3 minutes)
The purpose of the safety stop timer is
to allow you to monitor your safety stop
at the end of the dive. You can set the
duration of the safety stop timer between
1 and 5 minutes in one minute increments.
You can also set the timer to be triggered
automatically or manually or you can
turn the function OFF altogether. The
operation of the safety stop timer is
described in section 3.4.3.
2.3.4 ppO
2
max (default: 1.4bar)
The value of ppO
2
max determines your
MOD based on your oxygen mix. You can
set this value between 1.2bar and 1.6bar
or OFF.
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for UWATEC Galileo Terra at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of UWATEC Galileo Terra in the language / languages: English as an attachment in your email.

The manual is 1,8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of UWATEC Galileo Terra

UWATEC Galileo Terra User Manual - German - 66 pages

UWATEC Galileo Terra User Manual - Dutch - 64 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info