3. Diving with Galileo
3.5.2 Display information
When diving with an MB level other than L0, Galileo still carries out all calculations relating to
L0 in the background. To understand the relation between set MB level and the underlying
L0 calculation and how the information appears on the display, we shall use the example of
a dive with MB L3 set in the dive computer.
Situation
L3 information
on display
L0 information
in background
Display details
1
No-stop No-stop Display shows L3 no-stop time. L0 no-stop time can
be called up by pressing MORE.
2
Level stop No-stop Display shows L3 level stop information. The L3
information is in black on white background because
L0 is still in no-stop time. Stop is described as
LEVEL STOP. L0 no-stop time can be called up by
pressing MORE.
3
Level stop Decompression
3.1
Level stop is deeper than deco
stop
Display shows L3 level stop information. The L3
information is in white on a black background
because L0 is also in decompression. The stop
is described as LEVEL STOP because the stop
depth relates to the L3 level only. L0 decompression
information can be called up by pressing MORE.
3.2
Level stop is at same depth as
deco stop
Display shows L3 level stop information. The L3
information is in white on a black background
because L0 is also in decompression. The stop is
described as LEVEL+DECO STOP because the
stop depth is the same for L3 level and for L0. The
TAT (total ascent time) refers to L3 level stop, so as
the DECO STOP obligation is met, the description of
the stop depth changes from LEVEL+DECO STOP
to LEVEL STOP only. L0 decompression information
can be called up by pressing MORE.
Situation 2 Situation 3.1 Situation 3.2
3.5.3 Display of underlying L0 decompression information
During the dive, the information displayed is always relative to the active MB level. However,
in the CLASSIC, LIGHT and FULL display, the underlying L0 data is available as one of
the alternate information fi elds. When pressing the MORE button the appropriate number
of times, the L0 information will be visible instead of the active MB level information for
5 seconds, after which it is replaced again by the information relative to the active MB level.
While the L0 information is shown, the symbol L0 precedes either the word NO STOP or
DECO STOP. This allows you to be aware of what the maximum possible no-stop time is
or what the mandatory decompression requirements are.
For CLASSIC and LIGHT, the underlying L0 information is shown in the sequence right after the
active MB level and before the time of day. This is displayed for 5 seconds instead of the MB level
no-stop or decompression information. After 5 seconds it is replaced again by the information
relative to the active MB level.
60


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for UWATEC Galileo Sol at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of UWATEC Galileo Sol in the language / languages: English as an attachment in your email.

The manual is 2,24 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of UWATEC Galileo Sol

UWATEC Galileo Sol User Manual - German - 82 pages

UWATEC Galileo Sol User Manual - Dutch - 80 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info