6.6 RBT when diving with more
than one gas mixture
Galileo determines the RBT based on
your breathing pattern. The tanks with
the various gas mixtures you have with
you may be of different sizes, therefore
the RBT calculation cannot be extended
to all tanks at once since your breathing
pattern will be different for each tank. Since
Galileo performs several decompression
calculations simultaneously for all possible
combinations of gas mixtures, the RBT
calculation references the decompression
calculation that considers only the gas you
are currently breathing from.
- If you have programmed 2 or 3 gases
and are currently breathing from T1,
the RBT will be for the decompression
schedule that considers T1 only.
- If you have programmed 3 gases and
are currently breathing from T2, the RBT
will be for the decompression schedule
that considers T2 only.
- If you are breathing from TD, the RBT is
for the decompression calculation that
is actually displayed on the computer
screen.
6.7 Gauge mode and gas switching
By pressing and holding the left button,
you manually start the gas switch process.
The only result of switching gas mixtures
in gauge mode is that the pressure of the
newly chosen tank is displayed instead of
the current one. There are no restrictions
on when a gas switch can take place in
gauge mode. The message SWITCH TO
GAS T2 (or TD or T1, whichever is next in
sequence) appears on the display, and the
button labels change to SAVE (left) and >>
(middle). Press or press and hold the left
button (SAVE) to confirm the switch. Press
or press and hold the middle button (>>)
to move to the next tank in the sequence.
Press and hold the right button to interrupt
the gas switch procedure without carrying
out any switch. If the switch is completed,
the message SWITCH TO GAS T2 (or TD)
SUCCESSFUL appears on the display for
4 seconds.
6.8 Logbook for dives with more
than one gas mixture
For dives carried out with more than one gas
mixture, Galileo adds a page in the logbook
for each gas mixture. These appear just
before the page listing warnings and alarms.
Each page shows oxygen concentration,
starting pressure, end pressure, consumed
pressure and, for T2 and TD only, depth at
which the switch took place.
6.9 Planning dives with more than
one gas mixture
The dive planner considers all programmed
gas mixtures when computing no-stop
times or decompression schedules. When
more than one gas is set, the symbols T1,
T2 (if applicable) and TD appear on the dive
planner screen.
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for UWATEC Galileo Luna at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of UWATEC Galileo Luna in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 3,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of UWATEC Galileo Luna

UWATEC Galileo Luna User Manual - English - 72 pages

UWATEC Galileo Luna User Manual - German - 78 pages

UWATEC Galileo Luna User Manual - Dutch - 76 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info