550280
6
Zoom out
Zoom in
Previous page
1/82
Next page
4
programmed and used for diving with more
than one gas mixture whether you use
transmitters or not.
6.1 Setting the oxygen
concentration when diving with
more than one gas mixture
To set the oxygen concentration for tanks
T1, T2 and TD you need to access the
O
2
setting menu.
While TANK is highlighted, use the - and
+ buttons to choose the tank for which
you want to set the oxygen concentration.
Press >> to highlight ON or OFF, and use
the - and + buttons to toggle between the
two. Press >> again to move down one line
to the oxygen concentration. After setting
the oxygen concentration, pressing >>
moves you down one line to the ppO
2
max.
Note that the MOD for tanks T2 and TD
is actually the switch depth that Galileo
will use for its calculations, warnings and
suggested gas switch point. Press SAVE
to save your settings.
F
NOTE:
- Galileo considers in its algorithm
only gas mixtures whose tanks are
set to
ON in the O
2
settings menu.
- The oxygen concentration of T2
can only be set after having set the
oxygen concentration of TD.
- Setting the ppO
2
max value to OFF
applies to tank T1 only. Tanks T2 and
TD are always limited to a maximum
value of ppO
2
max of 1.6bar.
- For oxygen concentrations of 80%
and higher, the ppO
2
max is fixed at
1.6bar and cannot be changed.
- The oxygen concentration of T1
cannot be set to OFF.
- The oxygen concentration of T2
can only be set to a value between
that of T1 (equal or higher) and TD
(equal or lower).
- Galileo adds the label
T1, T2 or TD
next to the O
2
label and between
the tank pressure and RBT labels to
identify the currently active tank.
- The ON/OFF option for each
tank allows you to easily go from
3 to 2 or even to 1 gas mixture
without changing the actual oxygen
settings.
- If you set tank TD to OFF, T2 will
automatically be set to OFF also.
- The MOD for tanks T2 and TD is the
switch depth for the corresponding
gas. This is what Galileo uses for its
calculation, alarms and suggested
switch points.
- Galileo does not allow MODs of
different gases to be less than
3m/10ft apart.
- Setting a tank to OFF does not affect
the pairing of the corresponding
transmitter.
- When diving with more than one
gas mixture, the Nitrox reset time
function has the following effect:
o T1 is set to 21%
o T2 and TD are set to OFF.
6.2 Gas summary table
When more than one gas mixture is set,
Galileo lists the tank pressure, oxygen
concentration, pp
O
2
max and MOD for each
tank on the GAS SUMMARY TABLE. If a
tank designation has not been paired, NO P
appears instead of the pressure. If the tank
designation has been paired but Galileo is
not receiving a signal, “---” appears instead
of the pressure.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for UWATEC Galileo Luna at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of UWATEC Galileo Luna in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 3,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of UWATEC Galileo Luna

UWATEC Galileo Luna User Manual - English - 72 pages

UWATEC Galileo Luna User Manual - German - 78 pages

UWATEC Galileo Luna User Manual - Dutch - 76 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info